GasFurnace.caby BC Wide Heating & Air Conditioning

Carrier · Infinity 96 (59TN6B) · Model

Carrier Infinity 96 59TN6B 080C21–20

The 59TN6B 080C21–20 is the 80,000 BTU/h, 21-inch-wide Infinity 96: 52,000 BTU/h on low fire, 78,000 BTU/h output on high, 96.7% AFUE upflow and horizontal, with a 1 HP constant-airflow ECM blower. It is the family's highest-certified size and suits larger detached houses.

CurrentresidentialBC Wide service: confirm by phone

Rating plate

Model
59TN6B 080C21–20
Input
52,000 – 80,000 BTU/h
Output
51,000 – 78,000 BTU/h
AFUE
96.7% upflow · 95% down/horiz
Burner
Two-stage
Blower
ECM, constant airflow
Fuel
Natural gas / Propane
Cabinet
35 × 21 × 30 in
Canada
Available in Canada
Size designation as printed in Carrier product data 59TN6B-01PD. The complete number on the rating plate adds the voltage and minor-series digits; copy it from the plate when ordering parts.

At 80,000 BTU/h input this Infinity 96 delivers 78,000 BTU/h on high fire and 51,000 BTU/h on low, certified at 96.7% AFUE upflow and horizontal, the family's best figure, and 95.0% downflow. The 21-inch cabinet carries a 1 HP communicating constant-airflow blower that reaches 1,945 CFM for cooling at 0.5 in. w.c., enough for a 4.5- to 5.5-ton coil.

The 17.5-inch sibling (080C17–14) shares the same gas inputs, certifies 96.2% upflow and horizontal, and uses a 1/2 HP blower with a smaller 16-inch media cabinet; the wider 080C21–20 is chosen when cooling airflow matters more than cabinet width.

An 80,000 BTU/h input furnace is oversized for many modern Lower Mainland houses. Carrier's product data is explicit that excessive oversizing can shorten furnace and vent life; the size belongs to a heat-loss calculation, not to the old furnace's rating plate.

Specifications

From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.

Carrier Infinity 96 59TN6B 080C21–20 specifications
SpecificationValueNote
Input
Input, high heat80,000 BTU/h
Input, low heat52,000 BTU/h
Output
Output capacity, high heat78,000 BTU/hCarrier product data; DOE test procedure, position dependent.
Output capacity, low heat51,000 BTU/h
Efficiency
AFUE, upflow / horizontal96.7 %
AFUE, downflow95 %
Airflow
Certified temperature rise, high heat40 – 70 °F (22 – 39 °C)
Certified temperature rise, low heat30 – 60 °F (17 – 33 °C)
Airflow, high heat @ rated ESP1,345 CFM
Airflow, low heat @ rated ESP1,095 CFM
Cooling airflow range @ 0.5 in. w.c.750 – 1945 CFM
Cooling capacity match4.5 tons @ 400 CFM/ton; 5.5 tons @ 350 CFM/ton
Blower motorCommunicating variable-speed, constant-airflow (VCA) ECMMeasures and holds the airflow the control requests.
Physical
Cabinet width21 in533 mm
Cabinet depth30 in
Approximate shipping weight171.5 lb77.8 kg
Cabinet height35 in889 mm
Installation positionsUpflow, downflow, horizontal left, horizontal right
Venting
VentingDirect vent (2-pipe), single-pipe, or ventilated combustion airMaximum equivalent vent length depends on size, pipe diameter and altitude; see installation instructions.
Electrical
Blower motor1 HP
Maximum input amps13.6 A
Maximum fuse / breaker20 A
Electrical supply115 V, 60 Hz, 1 phase (104 – 127 V)
Controls
Burner stagingTwo-stage (low and high fire)
Other
Burners4
Factory-supplied media cabinet20 in (508 mm)
InducerTwo-speed
FuelNatural gas; propane with gas conversion accessory kit

Variants

Sizes that share this model page. A variant gets its own page only when it has substantial independent value.

Carrier Infinity 96 59TN6B 080C21–20 variants
SizeInput highInput lowOutput highOutput lowAFUE upflowAFUE down/horizWidth (in)Ship wt (lb)Cooling CFMMotor HP
080C21–2080,00052,00078,00051,00096.79521171.5750 – 19451
080C17–1480,00052,00078,00050,00096.29517.5152.5520 – 13101/2

Filters, serial numbers and service parts

Components this family's service documentation covers

  • Hot-surface ignitor
  • Flame sensor
  • Pressure switches
  • Inducer motor
  • Condensate trap and drain components
  • Constant-airflow ECM blower
  • Control board

Service-parts list source: Components documented for service in 59TN6B product data and service literature.

Best for

  • Larger detached homes whose heat-loss calculation supports the capacity
  • Homes building a communicating Infinity system with 4- to 5-ton cooling
  • Replacements where a heat-loss calculation confirms the size

Compatible controls

  • Communicating Infinity system with Infinity Control, Infinity air conditioner or heat pump
  • Compatible with single- and multiple-zone Infinity systems
  • Self-diagnostics and extended diagnostic data through the Advanced Product Monitor (APM) accessory or Infinity User Interface

System integrations

  • Infinity air conditioner or heat pump (dual-fuel) with communicating control
  • Infinity zoning for single- and multiple-zone systems
  • Factory-supplied external media filter cabinet

Manuals, codes and service

Compare

Guides that reference this model

This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.

Questions people ask

What is the difference between the 080C21–20 and the 080C17–14?

Same gas inputs. The 080C21–20 has the 21-inch cabinet, 1 HP blower (up to 1,945 CFM cooling airflow), 96.7% AFUE and a 20 in. media cabinet; the 080C17–14 uses a 17.5-inch cabinet, 1/2 HP blower and certifies 96.2%.

Can the Infinity 96 communicate with a heat pump?

Yes. It is designed for a complete Infinity System with an Infinity air conditioner or heat pump and an Infinity Control, which enables dual-fuel and staged operation through the communicating control.

Considering the 59TN6B 080C21–20?

Get a published ballpark range for a supply-and-install, then a consultation to confirm sizing from a heat-loss assessment. Equipment-only pricing is not offered on this site.

Call Email Estimate