Major code 23 means the control found a pressure switch already closed before the inducer started, when the switch should be open. Minor 23.1 is the main pressure switch stuck closed; minor 23.2 is the secondary pressure switch stuck closed.

Needs attentionnumeric

On the control

Code
23
Minor
23.1 · 23.2
Door LED
2 short flashes then 3 long
Controller
59SC6A integrated furnace control with 3-digit LCD display and door LED
Applies to
Carrier Comfort 96 (59SC6A)
Carrier's service label: the major code is shown on the door LED with the first digit as short flashes and the second digit as long flashes.

What each minor code says, verbatim

Sub-codes for Carrier code 23
DisplayManufacturer wording
23.1Stuck closed Main pressure switch
23.2Stuck closed secondary pressure switch

A code is a condition, not a diagnosis

A switch reported stuck closed can be the switch itself, but more often it is the sensing line: a disconnected or cracked hose, a blocked port holding the switch closed, or water in the line. The switch is tested with a manometer against its printed set-point.

Which furnaces this applies to

Documented for Carrier 59SC6A Comfort 96 furnaces in installation instructions 59SC6A-01SI REV D. The control checks that the switch contacts are open before starting the inducer, so a switch that fails closed or a sensing line that is off or blocked sets this code.

Scope: Carrier 59SC6A Comfort 96 furnaces with the on-board 3-digit display control. Not sure which control you have? Send us the full model number from the rating plate.

Safe things to look at first

  • Read the full code on the control display through the door, including any minor digit (for example 33.2), and write it down.
  • Look, without touching, for obvious conditions you can report: snow or ice at the vent terminations, water on the floor, a loaded filter, a condensate pump that is full or off.
  • Note whether the furnace still heats at all, and how long it runs before the code returns.
  • Note whether the furnace runs at all and whether the code appears at power-up or after a cycle.

Do not

  • Do not bypass or jumper the door switch, limit switches, rollout switches or pressure switches.
  • Do not open the burner compartment, disconnect tubing, or adjust the gas valve or gas pressure.
  • Do not keep cycling power to force the furnace to relight; repeated resets hide the fault and can allow unburned gas to build up after ignition failures. If the code returns, stop and call.

What a technician does

  • A technician checks the switch contacts with power off, inspects the hoses and ports, verifies the switch opens at its printed break point with a manometer, and checks the condensate path before replacing anything.

Same code, other equipment

  • Carrier 59TP6C two-stage controls: The two-stage Performance 96 prints the same major 23 with sub-codes 23.4 and 23.5 (LPS and HPS stuck closed). Sub-code numbers differ between stages; read the label on your furnace.

Related components and symptoms

Questions people ask

What does a stuck-closed pressure switch mean for my furnace?

The control refuses to start the burner because a switch that should be open is closed, which could let the control misread the draft condition. It is a safety check doing its job; the cause is found by testing the switch and its tubing.