Carrier · Status code
Carrier 59SC6A status code 24.1: fuse fault
Status code 24.1 means the 3-amp automotive-type fuse on the furnace control has blown. Any short in the 24 V wiring during installation, service or maintenance will blow this fuse, and the control displays 24.1 when it needs replacement.
On the control
- Code
- 24
- Minor
- 24.1
- Door LED
- 2 short flashes then 4 long
- Controller
- 59SC6A integrated furnace control with 3-digit LCD display and door LED
- Applies to
- Carrier Comfort 96 (59SC6A)
- Manual
- 59SC6A-01SI REV D
What each minor code says, verbatim
| Display | Manufacturer wording |
|---|---|
| 24.1 | Fuse fault |
A code is a condition, not a diagnosis
A blown fuse is the symptom, not the fault. The short that blew it must be found before a new fuse is fitted: a pinched wire, a shorted thermostat cable, a faulty 24 V accessory, or work done with power on.
Which furnaces this applies to
Documented for Carrier 59SC6A Comfort 96 furnaces in installation instructions 59SC6A-01SI REV D. Only a 3-amp fuse may be used as a replacement.
Scope: Carrier 59SC6A Comfort 96 furnaces with the on-board 3-digit display control. Not sure which control you have? Send us the full model number from the rating plate.
Safe things to look at first
- Read the full code on the control display through the door, including any minor digit (for example 33.2), and write it down.
- Look, without touching, for obvious conditions you can report: snow or ice at the vent terminations, water on the floor, a loaded filter, a condensate pump that is full or off.
- Note whether the furnace still heats at all, and how long it runs before the code returns.
- Note anything recently changed or serviced on the furnace, thermostat or 24 V accessories, and look for water near the wiring.
Do not
- Do not replace the fuse with anything other than a 3-amp fuse as specified by Carrier.
- Do not bypass the fuse with wire or a larger fuse; the fuse protects the low-voltage circuit.
- Do not keep cycling power to force the furnace to relight; if the code returns, stop and call.
What a technician does
- A technician isolates power, finds and corrects the short, then replaces the fuse with the correct 3-amp part and verifies the control operates.
Related components and symptoms
Questions people ask
Can I replace the 24 V fuse myself?
Replacing the fuse is simple, but the short that blew it is not. If a fresh 3-amp fuse blows again, the wiring fault must be traced; BC Wide replaces it as part of the diagnosis.