Carrier · Performance 97 (59TP7A) · Model
Carrier Performance 97 59TP7A 060V17–16
The 59TP7A 060V17–16 is the 60,000 BTU/h size of Carrier's Performance 97 two-stage furnace: 39,000 BTU/h on low fire, 58,000 BTU/h output on high, 97.0% AFUE upflow, with a 3/4 HP variable-speed ECM blower. It is the entry size of the 97% family.
Rating plate
- Model
- 59TP7A 060V17–16
- Input
- 39,000 – 60,000 BTU/h
- Output
- 38,000 – 58,000 BTU/h
- AFUE
- 97% upflow · 95% down/horiz
- Burner
- Two-stage
- Blower
- ECM, constant torque (variable-speed)
- Fuel
- Natural gas / Propane
- Cabinet
- 35 × 17.5 × 29.5 in
- Canada
- Available in Canada
The Performance 97's smallest size keeps the two-stage story of its 96 sibling and adds a certified efficiency step: 97.0% AFUE upflow, 96.3% horizontal and 95.0% downflow in Carrier's product data. Low fire is 39,000 BTU/h input and 38,000 BTU/h output; high fire is 60,000 BTU/h input and 58,000 BTU/h output.
The 17.5-inch cabinet carries a 3/4 HP variable 25-speed ECM blower that reaches 1,565 CFM for cooling, matching the 060V17–16 of the Performance 96 cabinet for cabinet. The certified low-heat temperature rise range is narrower on this family (25 to 55 °F), which reflects its airflow settings rather than a different heat exchanger.
There is no smaller size in the Performance 97 family, so houses whose heat-loss calculation lands below this furnace step down to the Performance 96 or Comfort 96. Whether 60,000 BTU/h input suits a given house is a heat-loss question; Carrier's product data repeats the standing warning against excessive oversizing.
Specifications
From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, high heat | 60,000 BTU/h | |
| Input, low heat | 39,000 BTU/h | |
| Output | ||
| Output capacity, high heat | 58,000 BTU/h | Carrier product data; DOE test procedure, position dependent. |
| Output capacity, low heat | 38,000 BTU/h | |
| Efficiency | ||
| AFUE, upflow | 97 % | |
| AFUE, horizontal | 96.3 % | |
| AFUE, downflow | 95 % | |
| Airflow | ||
| Certified temperature rise, low heat | 25 – 55 °F (14 – 31 °C) | |
| Airflow, high heat @ rated ESP | 1,030 CFM | |
| Airflow, low heat @ rated ESP | 890 CFM | |
| Cooling airflow range | 345 – 1565 CFM | |
| Cooling capacity match | 3.5 tons @ 400 CFM/ton; 4 tons @ 350 CFM/ton | |
| Blower motor | Variable 25-speed, constant-torque (VCT) ECM | Not a constant-airflow motor; it does not report airflow to the control. |
| Certified temperature rise, high heat | 40 – 70 °F (22 – 39 °C) | |
| Physical | ||
| Cabinet width | 17.5 in | 445 mm |
| Shipping weight | 146 lb | 66.2 kg |
| Cabinet height | 35 in | 889 mm |
| Cabinet depth | 29.5 in | 750 mm |
| Installation positions | Upflow, downflow, horizontal left, horizontal right | |
| Venting | ||
| Venting | Direct vent (2-pipe), single-pipe, or ventilated combustion air; 2-in., 3-in. or optional 4-in. termination | Maximum equivalent vent length depends on size, pipe diameter and altitude; see installation instructions. |
| Electrical | ||
| Blower motor | 3/4 HP | |
| Maximum unit amps | 10.1 A | |
| Maximum fuse / breaker | 15 A | |
| Electrical supply | 115 V, 60 Hz, 1 phase (104 – 127 V) | |
| Controls | ||
| Burner staging | Two-stage (low and high fire) | |
| Other | ||
| Burners | 3 | |
| Inducer | Two-speed | |
| Fuel | Natural gas; propane with gas conversion accessory kit | |
Filters, serial numbers and service parts
Filter
- Field-supplied filter; certified watt data uses Carrier media filter 325531-40
Components this family's service documentation covers
- Hot-surface ignitor
- Flame sensor
- Pressure switches (LPS/HPS)
- Inducer motor
- Condensate trap and drain components
- ECM blower motor
- Control board
Service-parts list source: Components documented for service in 59TP7A-01SI.
Warranty coverage, registered or not
- Registered
- 10-year parts and lifetime limited heat exchanger warranty
- Not registered
- Default 5-year parts and 20-year heat exchanger limited warranty
As published by the manufacturer. Source. Conditions and exceptions are in the warranty certificate.
Fault codes this model can show
Best for
- Detached homes whose design heat loss sits at or near the 58,000 BTU/h high-fire output
- Homes wanting the top upflow AFUE point (97.0%) at a moderate capacity
- Houses pairing the furnace with an air conditioner or heat pump up to about 3.5 tons
Compatible controls
- Standard 24 V thermostat terminals: G, C, W, Y/Y2, Y1, R, DHUM
- ecobee for Carrier smart thermostat with InteliSense technology (InteliSense capable)
- On-board 3-digit LCD control display for set-up, diagnostics and fault history
System integrations
- Air conditioner or heat pump (dual-fuel / Hybrid Heat) with a compatible thermostat
- Twinning of two furnaces with the accessory kit
- Field-supplied filter or optional media filter cabinet
Warranty, as published
Default 5-year parts limited warranty and 20-year heat exchanger limited warranty; 10-year parts and lifetime limited heat exchanger warranty with timely registration.
Register within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration. Original purchaser/homeowner only; see the warranty certificate. Source
BC Wide can help with registration and warranty enquiries for furnaces it installs or services. Ask about warranty support.
Manuals, codes and service
Documents
Fault codes that apply
- Code 31: high-heat pressure switch (HPS) open or slow to close
- Code 10: rapid flash - L1 polarity fault
- Code 12: W on at power up
- Code 13: limit lockout or ignition lockout
- Code 14: flame-loss lockouts during a heat request
- Code 15: lockout - no blower rpms detected
- Code 19: InteliSense communications loss
- Code 21: 24 VAC sensed on the gas valve when it shouldn't be
- Code 22: false flame
- Code 23: pressure switch stuck closed
- Code 24: fuse fault
- Code 25: control program and configuration faults
- Code 27: super plug or control program fault
- Code 32: open main pressure switch (LPS)
- Code 33: limit circuit, high-heat or ignition lockout
- Code 34: flame lost after ignition
- Code 41: blower RPM not detected
- Code 43: HPS closed before LPS
- Code 45: control failure
- Code 46: momentary loss of power
- Code 52: supply-air temperature sensor open or short
- Code 53: return-air temperature sensor open or short
BC Wide service
This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.
Questions people ask
Is the 97% AFUE worth the difference from the Performance 96?
The Performance 97 certifies 97.0% upflow versus 96.1–96.7% for the 96 family. The real-world gas difference is roughly one dollar per hundred. The staging and blower are the same generation, so the choice is efficiency and availability, not comfort.
Why is the horizontal AFUE different from the downflow AFUE?
Carrier publishes separate certified figures for this family: 97.0% upflow, 96.3% horizontal and 95.0% downflow for this size. The rating plate states the figure for the installed position.
Considering the 59TP7A 060V17–16?