GasFurnace.caby BC Wide Heating & Air Conditioning

Carrier · Performance 96 single-stage (59SP6B) · Model

Carrier Performance 96 single-stage 59SP6B 120V24–22

The 59SP6B 120V24–22 is the largest single-stage Performance 96: 120,000 BTU/h input, 116,000 BTU/h output at one gas rate, 96.1% AFUE upflow, in a 24.5-inch cabinet with six burners. It is a specialist size for genuinely large or poorly insulated houses.

CurrentresidentialBC Wide service: confirm by phone

Rating plate

Model
59SP6B 120V24–22
Input
undefined – 120,000 BTU/h
Output
undefined – 116,000 BTU/h
AFUE
96.1% upflow · 95% down/horiz
Burner
Single-stage
Blower
ECM, constant torque (variable-speed)
Fuel
Natural gas / Propane
Cabinet
35 × 24.5 × 29.5 in
Canada
Available in Canada
Size designation as printed in Carrier product data 59SP6B-01PD. The complete number on the rating plate adds the voltage and minor-series digits; copy it from the plate when ordering parts.

The top of the single-stage Performance 96 family delivers 116,000 BTU/h on every heating call from six burners, certified at 96.1% AFUE upflow and 95% downflow and horizontal. At 186 lb in a 24.5-inch cabinet, it is a large appliance that needs a mechanical room and a duct system built for it.

The 1 HP variable 25-speed ECM blower moves 1,955 CFM in heating and up to 2,245 CFM for cooling, and the 20 A maximum breaker with 12 AWG wire suits the draw. In the Lower Mainland this size appears most replacing an old large furnace in a big older house where the heat-loss calculation confirms the capacity.

A furnace this size firing at full rate on every call is a blunt instrument for mild weather: if the house rarely needs full fire, the two-stage Performance 96 at the same capacity serves it more gently. Carrier's product data repeats the standing warning that oversizing can shorten furnace and vent life.

Specifications

From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.

Carrier Performance 96 single-stage 59SP6B 120V24–22 specifications
SpecificationValueNote
Input
Input120,000 BTU/h
Output
Output capacity116,000 BTU/hCarrier product data; DOE test procedure, position dependent.
Efficiency
AFUE, upflow96.1 %
AFUE, downflow / horizontal95 %
Airflow
Airflow, heating @ rated ESP1,955 CFM
Cooling airflow range350 – 2245 CFM
Cooling capacity match5 tons @ 400 CFM/ton; 6 tons @ 350 CFM/ton
Blower motorVariable 25-speed, constant-torque (VCT) ECMNot a constant-airflow motor; it does not report airflow to the control.
Certified temperature rise range40 – 70 °F (22 – 39 °C)
Physical
Cabinet width24.5 in622 mm
Shipping weight186 lb84.4 kg
Cabinet height35 in889 mm
Cabinet depth29.5 in750 mm
Installation positionsUpflow, downflow, horizontal left, horizontal right
Venting
VentingDirect vent (2-pipe), single-pipe, or ventilated combustion airMaximum equivalent vent length depends on size, pipe diameter and altitude; see installation instructions.
Electrical
Blower motor1 HP
Maximum unit amps12.6 A
Maximum fuse / breaker20 A
Electrical supply115 V, 60 Hz, 1 phase (104 – 127 V)
Controls
Burner stagingSingle-stage (full fire on every call)
Other
Burners6
InducerSingle-speed
FuelNatural gas; propane with gas conversion accessory kit

Filters, serial numbers and service parts

Filter

  • Field-supplied filter; certified watt data uses Carrier media filter 325531-40

Components this family's service documentation covers

  • Hot-surface ignitor
  • Flame sensor
  • Pressure switches
  • Inducer motor
  • Condensate trap and drain components
  • ECM blower motor
  • Control board

Service-parts list source: Components documented for service in 59SP6B-01SI REV B.

Warranty coverage, registered or not

Registered
10-year parts and lifetime limited heat exchanger warranty
Not registered
Default 5-year parts and 20-year heat exchanger limited warranty

As published by the manufacturer. Source. Conditions and exceptions are in the warranty certificate.

Fault codes this model can show

Best for

  • Large detached houses and older homes with high verified design heat loss
  • Houses whose duct system is built to move 2,000+ CFM and can take a 24.5-inch cabinet
  • Replacements where the heat-loss calculation confirms the capacity

Compatible controls

  • Standard 24 V thermostat terminals: G, C, W, Y/Y2, Y1, R, DHUM
  • ecobee for Carrier smart thermostat with InteliSense technology (InteliSense capable)
  • On-board 3-digit LCD control display with ComfortFan continuous-fan control

System integrations

  • Air conditioner or heat pump (dual-fuel / Hybrid Heat) with a compatible thermostat
  • Twinning of two furnaces with the accessory kit
  • Field-supplied filter or optional media filter cabinet

Warranty, as published

Default 5-year parts limited warranty and 20-year heat exchanger limited warranty; 10-year parts and lifetime limited heat exchanger warranty with timely registration.

Register within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration. Original purchaser/homeowner only; see the warranty certificate. Source

BC Wide can help with registration and warranty enquiries for furnaces it installs or services. Ask about warranty support.

Manuals, codes and service

This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.

Questions people ask

Is there a larger single-stage Performance 96?

No. The 59SP6B family tops out at 120,000 BTU/h input. Larger single-stage capacity is available in the Comfort 96 line (140,000 BTU/h) and in historical Carrier models documented on this site.

Why choose this over the two-stage 120,000 BTU/h Performance 96?

First cost and simplicity. The two-stage version carries most mild-weather cycles on low fire, which is gentler on a large house; if the calculation shows the house genuinely needs 116,000 BTU/h of output, compare both in the proposal.

Considering the 59SP6B 120V24–22?

Get a published ballpark range for a supply-and-install, then a consultation to confirm sizing from a heat-loss assessment. Equipment-only pricing is not offered on this site.

Call Email Estimate