GasFurnace.caby BC Wide Heating & Air Conditioning

Carrier · Comfort 96 (59SC6A) · Model

Carrier Comfort 96 59SC6A 120M24–22

The 59SC6A 120M24–22 is the 120,000 BTU/h, 24.5-inch-wide Comfort 96: 116,000 BTU/h output on a single gas rate, 96.1% AFUE upflow, with six burners and a 1 HP multi-speed ECM blower. It is a specialist size for genuinely large or poorly insulated houses.

CurrentresidentialBC Wide service: confirm by phone

Rating plate

Model
59SC6A 120M24–22
Input
undefined – 120,000 BTU/h
Output
undefined – 116,000 BTU/h
AFUE
96.1% upflow · 95% down/horiz
Burner
Single-stage
Blower
ECM, constant torque (variable-speed)
Fuel
Natural gas / Propane
Cabinet
35 × 24.5 × 29.5 in
Canada
Available in Canada
Size designation as printed in Carrier product data 59SC6A-01PD. The complete number on the rating plate adds the voltage and minor-series digits; copy it from the plate when ordering parts.

At this capacity the Comfort 96 is a large appliance that delivers 116,000 BTU/h at full fire on every call, drawing its heat from six burners. The 24.5-inch cabinet, 181 lb shipping weight and 1 HP blower (up to 2,240 CFM of cooling airflow) need a mechanical room that fits them and a duct system that can move the air.

Carrier certifies this size at 96.1% AFUE upflow and 95% downflow, with a 15 A maximum breaker despite its size, thanks to the ECM motor. In the Lower Mainland it appears most replacing an old large furnace in a big older house where the heat-loss calculation confirms the capacity, not as a first choice for new construction.

The honest caution applies at this end of the range as strongly as at the small end: an oversized furnace short-cycles, wears its parts and can freeze or flood its own vent in mild weather. The size is chosen from the calculation, never from the old furnace's rating plate alone.

Specifications

From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.

Carrier Comfort 96 59SC6A 120M24–22 specifications
SpecificationValueNote
Input
Input120,000 BTU/h
Output
Output capacity116,000 BTU/hCarrier product data; DOE test procedure, position dependent.
Efficiency
AFUE, upflow / horizontal96.1 %
AFUE, downflow95 %
Airflow
Certified temperature rise range40 – 70 °F (22 – 39 °C)
Airflow, heating @ rated ESP1,965 CFM
Cooling airflow range290 – 2240 CFM
Blower motorMulti 18-speed, constant-torque (MCT) ECMNot a communicating constant-airflow motor; speeds are installer-selectable.
Physical
Cabinet width24.5 in622 mm
Shipping weight181 lb82 kg
Cabinet height35 in889 mm
Cabinet depth29.5 in750 mm
Installation positionsUpflow, downflow, horizontal left, horizontal right
Venting
VentingDirect vent (2-pipe), single-pipe, or ventilated combustion air on sizes above 26,000 BTU/h; the 26,000 BTU/h size uses 2-pipe venting with outside combustion air and is not classed as direct-vent
Electrical
Blower motor1 HP
Maximum unit amps13.2 A
Maximum fuse / breaker15 A
Electrical supply115 V, 60 Hz, 1 phase (104 – 127 V)
Controls
Burner stagingSingle-stage (full fire on every call)
Other
Burners6
InducerSingle-speed
FuelNatural gas; propane with gas conversion accessory kit

Filters, serial numbers and service parts

Filter

  • Field-supplied filter; certified watt data uses Carrier media filter 325531-40

Components this family's service documentation covers

  • Hot-surface ignitor
  • Flame sensor
  • Pressure switches
  • Inducer motor
  • Condensate trap and drain components
  • ECM blower motor
  • Control board

Service-parts list source: Components documented for service in 59SC6A-01SI REV D.

Fault codes this model can show

Best for

  • Large detached houses and older homes with high verified design heat loss
  • Houses whose duct system is built to move 2,000+ CFM and can take a 24.5-inch cabinet
  • Replacements where the calculation confirms capacity above the 100,000 BTU/h sizes

Compatible controls

  • Standard 24 V thermostat terminals: G, C, W, Y, R
  • On-board 3-digit status display with NFC setup via the Carrier service technician app
  • EAC-1 (115 VAC), HUM (24 VAC) and 1-stage AC accessory connections

System integrations

  • Air conditioner or heat pump (dual-fuel / Hybrid Heat) with a compatible thermostat
  • Twinning of two furnaces with the accessory kit (selected sizes only)
  • Manufactured (mobile) home applications with the MH accessory kit (selected sizes)
  • Field-supplied filter or optional media filter cabinet

Manuals, codes and service

This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.

Questions people ask

Why would anyone choose the single-stage Comfort 96 at 120,000 BTU/h?

When the house truly needs the capacity and the owner's priority is the lowest first cost among 95%+ furnaces. The trade-off is full-fire cycling; Carrier's two-stage Performance 96 at this capacity is gentler but costs more.

Does this furnace need a big electrical circuit?

No. Carrier's product data lists a 15 A maximum fuse or circuit breaker with 14 AWG minimum wire for the whole 59SC6A family, including this size.

Considering the 59SC6A 120M24–22?

Get a published ballpark range for a supply-and-install, then a consultation to confirm sizing from a heat-loss assessment. Equipment-only pricing is not offered on this site.

Call Email Estimate