GasFurnace.caby BC Wide Heating & Air Conditioning

Carrier · Infinity 97 (59TN7A) · Model

Carrier Infinity 97 59TN7A 060C17–16

The 59TN7A 060C17–16 is the 60,000 BTU/h size of Carrier's communicating Infinity 97: 39,000 BTU/h on low fire, 58,000 BTU/h output on high, 97.0% AFUE upflow, with a 3/4 HP constant-airflow ECM blower. It is the entry size of the 97% communicating family.

CurrentresidentialBC Wide service: confirm by phone

Rating plate

Model
59TN7A 060C17–16
Input
39,000 – 60,000 BTU/h
Output
38,000 – 58,000 BTU/h
AFUE
97% upflow · 95% down/horiz
Burner
Two-stage
Blower
ECM, constant airflow
Fuel
Natural gas / Propane
Cabinet
35 × 17.5 × 29.5 in
Canada
Available in Canada
Size designation as printed in Carrier product data 59TN7A-01PD. The complete number on the rating plate adds the voltage and minor-series digits; copy it from the plate when ordering parts.

The smallest Infinity 97 runs the communicating two-stage system at 39,000 BTU/h input and 38,000 BTU/h output on low fire, and 60,000 BTU/h input and 58,000 BTU/h output on high. Carrier certifies 97.0% AFUE upflow, 96.3% horizontal and 95.0% downflow for this size, with a low-heat certified temperature rise of 25 to 55 °F.

The 3/4 HP communicating constant-airflow blower delivers 984 CFM in high heat and 1,270 CFM for cooling at rated static pressure, and the control board carries the current-generation 3-digit display, NFC setup and RAT/SAT thermistor connections. Like every Infinity 97, it is built to run with an Infinity Control, Infinity cooling and Infinity zoning.

At 60,000 BTU/h input this size suits compact detached houses and larger suites whose heat-loss calculation supports it. Carrier's product data repeats the family sizing rule: none of the sizes may be used where the heating load is 20,000 BTU/h or lower, and excessive oversizing can shorten furnace and vent life.

Specifications

From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.

Carrier Infinity 97 59TN7A 060C17–16 specifications
SpecificationValueNote
Input
Input, high heat60,000 BTU/h
Input, low heat39,000 BTU/h
Output
Output capacity, high heat58,000 BTU/hCarrier product data; DOE test procedure, position dependent.
Output capacity, low heat38,000 BTU/h
Efficiency
AFUE, upflow97 %
AFUE, horizontal96.3 %
AFUE, downflow95 %
Airflow
Certified temperature rise, high heat40 – 70 °F (22 – 39 °C)
Certified temperature rise, low heat25 – 55 °F (14 – 31 °C)
Airflow, high heat @ rated ESP984 CFM
Airflow, low heat @ rated ESP897 CFM
Cooling airflow @ 0.5 in. w.c.1,270 CFM
Cooling capacity match3 tons @ 400 CFM/ton; 3.5 tons @ 350 CFM/ton
Blower motorCommunicating variable-speed, constant-airflow (VCA) ECMMeasures and holds the airflow the control requests.
Physical
Cabinet width17.5 in445 mm
Cabinet depth29.5 in
Approximate shipping weight151 lb68.5 kg
Cabinet height35 in889 mm
Installation positionsUpflow, downflow, horizontal left, horizontal right
Venting
VentingDirect vent (2-pipe), single-pipe, or ventilated combustion airMaximum equivalent vent length depends on size, pipe diameter and altitude; see installation instructions.
Electrical
Blower motor3/4 HP
Maximum unit amps10.1 A
Maximum fuse / breaker15 A
Electrical supply115 V, 60 Hz, 1 phase (104 – 127 V)
Controls
Burner stagingTwo-stage (low and high fire)
Other
Burners3
InducerTwo-speed
FuelNatural gas; propane with gas conversion accessory kit

Filters, serial numbers and service parts

Filter

  • Field-supplied filter; certified watt data uses Carrier media filter 325531-40

Components this family's service documentation covers

  • Hot-surface ignitor
  • Flame sensor
  • Pressure switches (LPS/HPS)
  • Inducer motor
  • Condensate trap and drain components
  • Constant-airflow ECM blower
  • Control board

Service-parts list source: Components documented for service in 59TN7A-01SI.

Warranty coverage, registered or not

Registered
10-year parts and lifetime limited heat exchanger warranty
Not registered
Default 5-year parts and 20-year heat exchanger limited warranty

As published by the manufacturer. Source. Conditions and exceptions are in the warranty certificate.

Fault codes this model can show

Best for

  • Compact detached houses and larger suites with modest verified design heat loss
  • Homes building a communicating Infinity system with Infinity Control and Infinity cooling
  • Buyers who want 97% upflow efficiency with constant-airflow blower behaviour

Compatible controls

  • Communicating Infinity system with Infinity Control, Infinity zoning and Infinity cooling
  • 3-digit display showing fault codes and furnace status, with NFC setup via the Carrier service technician app
  • RAT and SAT thermistor connections for temperature rise

System integrations

  • Infinity air conditioner or heat pump (dual-fuel) with communicating control
  • Infinity zoning for single- and multiple-zone systems
  • Field-supplied filter or optional media filter cabinet

Warranty, as published

Default 5-year parts limited warranty and 20-year heat exchanger limited warranty; 10-year parts and lifetime limited heat exchanger warranty with timely registration.

Register within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration. Original purchaser/homeowner only; see the warranty certificate. Source

BC Wide can help with registration and warranty enquiries for furnaces it installs or services. Ask about warranty support.

Manuals, codes and service

This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.

Questions people ask

How is the Infinity 97 different from the two-stage Performance 97?

The Infinity 97 is communicating: it runs with an Infinity Control and Infinity cooling and zoning, and its blower is a constant-airflow motor that reports and holds airflow. The Performance 97 is non-communicating with a constant-torque blower.

Does this furnace have a 3-digit display like the Performance furnaces?

Yes. The 59TN7A product data lists a 3-digit display showing fault codes and furnace status, plus NFC setup through the Carrier service technician app.

Considering the 59TN7A 060C17–16?

Get a published ballpark range for a supply-and-install, then a consultation to confirm sizing from a heat-loss assessment. Equipment-only pricing is not offered on this site.

Call Email Estimate