GasFurnace.caby BC Wide Heating & Air Conditioning

Carrier · Infinity 96 (59TN6B) · Model

Carrier Infinity 96 59TN6B 120C24–22

The 59TN6B 120C24–22 is the largest Infinity 96: 120,000 BTU/h input, 78,000 BTU/h on low fire, 117,000 BTU/h output on high, 96.7% AFUE upflow and horizontal, in a 24.5-inch cabinet with six burners. It is a specialist size for genuinely large houses.

CurrentresidentialBC Wide service: confirm by phone

Rating plate

Model
59TN6B 120C24–22
Input
78,000 – 120,000 BTU/h
Output
76,000 – 117,000 BTU/h
AFUE
96.7% upflow · 95% down/horiz
Burner
Two-stage
Blower
ECM, constant airflow
Fuel
Natural gas / Propane
Cabinet
35 × 24.5 × 30 in
Canada
Available in Canada
Size designation as printed in Carrier product data 59TN6B-01PD. The complete number on the rating plate adds the voltage and minor-series digits; copy it from the plate when ordering parts.

The top of the Infinity 96 family delivers 117,000 BTU/h on high fire from 120,000 BTU/h of input, with low fire at 78,000 BTU/h input and 76,000 BTU/h output. Its certified 96.7% AFUE upflow and horizontal ties the 080C21–20 for the family's best figure; downflow certifies at 95.0%.

At 195 lb with a 24.5-inch cabinet, six burners, a 1 HP communicating blower and a factory-supplied 24-inch media cabinet, this is a large appliance that needs a mechanical room and a duct system built for it. The blower moves 1,820 CFM in high heat and up to 2,135 CFM for cooling.

In the Lower Mainland this size appears most replacing an old large furnace in a big older house where the heat-loss calculation confirms the capacity. Carrier's product data repeats the standing warning that excessive oversizing can shorten furnace and vent life; the calculation decides, not the old furnace.

Specifications

From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.

Carrier Infinity 96 59TN6B 120C24–22 specifications
SpecificationValueNote
Input
Input, high heat120,000 BTU/h
Input, low heat78,000 BTU/h
Output
Output capacity, high heat117,000 BTU/hCarrier product data; DOE test procedure, position dependent.
Output capacity, low heat76,000 BTU/h
Efficiency
AFUE, upflow / horizontal96.7 %
AFUE, downflow95 %
Airflow
Certified temperature rise, high heat45 – 75 °F (25 – 42 °C)
Certified temperature rise, low heat30 – 60 °F (17 – 33 °C)
Airflow, high heat @ rated ESP1,820 CFM
Airflow, low heat @ rated ESP1,555 CFM
Cooling airflow range @ 0.5 in. w.c.705 – 2135 CFM
Cooling capacity match5.5 tons @ 400 CFM/ton; 6 tons @ 350 CFM/ton
Blower motorCommunicating variable-speed, constant-airflow (VCA) ECMMeasures and holds the airflow the control requests.
Physical
Cabinet width24.5 in622 mm
Cabinet depth30 in
Approximate shipping weight195 lb88.4 kg
Cabinet height35 in889 mm
Installation positionsUpflow, downflow, horizontal left, horizontal right
Venting
VentingDirect vent (2-pipe), single-pipe, or ventilated combustion airMaximum equivalent vent length depends on size, pipe diameter and altitude; see installation instructions.
Electrical
Blower motor1 HP
Maximum input amps13.7 A
Maximum fuse / breaker20 A
Electrical supply115 V, 60 Hz, 1 phase (104 – 127 V)
Controls
Burner stagingTwo-stage (low and high fire)
Other
Burners6
Factory-supplied media cabinet24 in (609 mm)
InducerTwo-speed
FuelNatural gas; propane with gas conversion accessory kit

Filters, serial numbers and service parts

Components this family's service documentation covers

  • Hot-surface ignitor
  • Flame sensor
  • Pressure switches
  • Inducer motor
  • Condensate trap and drain components
  • Constant-airflow ECM blower
  • Control board

Service-parts list source: Components documented for service in 59TN6B product data and service literature.

Best for

  • Large detached houses and older homes with high verified design heat loss
  • Communicating Infinity systems in houses whose ducts move 2,000+ CFM
  • Replacements where the heat-loss calculation confirms capacity above the 100,000 BTU/h size

Compatible controls

  • Communicating Infinity system with Infinity Control, Infinity air conditioner or heat pump
  • Compatible with single- and multiple-zone Infinity systems
  • Self-diagnostics and extended diagnostic data through the Advanced Product Monitor (APM) accessory or Infinity User Interface

System integrations

  • Infinity air conditioner or heat pump (dual-fuel) with communicating control
  • Infinity zoning for single- and multiple-zone systems
  • Factory-supplied external media filter cabinet

Manuals, codes and service

This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.

Questions people ask

Does the Infinity 96 come any larger than this?

No. The 59TN6B family has five sizes ending at the 120C24–22. Larger communicating capacity sits in the Infinity 97 and Infinity 98 families at similar cabinet sizes.

Why does the largest size match the 96.7% figure of the 080C21–20?

Certified AFUE is per size, not per cabinet: Carrier publishes 96.7% for both the 080C21–20 and the 120C24–22, with 96.3%, 96.2% and 96.1% on the other sizes.

Considering the 59TN6B 120C24–22?

Get a published ballpark range for a supply-and-install, then a consultation to confirm sizing from a heat-loss assessment. Equipment-only pricing is not offered on this site.