GasFurnace.caby BC Wide Heating & Air Conditioning

Carrier · Performance 96 single-stage (59SP6B) · Model

Carrier Performance 96 single-stage 59SP6B 040V17–12

The 59SP6B 040V17–12 is the 40,000 BTU/h, 17.5-inch-wide single-stage Performance 96: 39,000 BTU/h output at one gas rate, 96.7% AFUE upflow, with a 1/2 HP variable-speed ECM blower. It is the single-stage size most often discussed for compact detached houses and larger suites.

CurrentresidentialBC Wide service: confirm by phone

Rating plate

Model
59SP6B 040V17–12
Input
undefined – 40,000 BTU/h
Output
undefined – 39,000 BTU/h
AFUE
96.7% upflow · 95% down/horiz
Burner
Single-stage
Blower
ECM, constant torque (variable-speed)
Fuel
Natural gas / Propane
Cabinet
35 × 17.5 × 29.5 in
Canada
Available in Canada
Size designation as printed in Carrier product data 59SP6B-01PD. The complete number on the rating plate adds the voltage and minor-series digits; copy it from the plate when ordering parts.

Every call for heat runs this furnace at its one gas rate: 40,000 BTU/h in and 39,000 BTU/h out until the thermostat is satisfied. The single-stage Performance 96 is Carrier's answer for buyers who want the Performance controls and blower without paying for two-stage firing, and Carrier certifies this size at 96.7% AFUE upflow and 95% downflow and horizontal.

The 17.5-inch cabinet pairs two burners with a 1/2 HP variable 25-speed ECM blower reaching 1,105 CFM for cooling, and the same 3-digit display control and InteliSense option as the two-stage Performance models. The 14.2-inch sibling (040V14–10) delivers the same heat at 96.0% upflow for narrow closets.

A 40,000 BTU/h input furnace serves many well-insulated Lower Mainland houses, but the size decision belongs to a heat-loss calculation. Carrier's product data warns that excessive oversizing can shorten furnace and vent life, and that none of its sizes may be used where the heating load is 20,000 BTU/h or lower.

Specifications

From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.

Carrier Performance 96 single-stage 59SP6B 040V17–12 specifications
SpecificationValueNote
Input
Input40,000 BTU/h
Output
Output capacity39,000 BTU/hCarrier product data; DOE test procedure, position dependent.
Efficiency
AFUE, upflow96.7 %
AFUE, downflow / horizontal95 %
Airflow
Airflow, heating @ rated ESP715 CFM
Cooling airflow range205 – 1105 CFM
Cooling capacity match2.5 tons @ 400 CFM/ton; 3 tons @ 350 CFM/ton
Blower motorVariable 25-speed, constant-torque (VCT) ECMNot a constant-airflow motor; it does not report airflow to the control.
Certified temperature rise range40 – 70 °F (22 – 39 °C)
Physical
Cabinet width17.5 in445 mm
Shipping weight134 lb60.8 kg
Cabinet height35 in889 mm
Cabinet depth29.5 in750 mm
Installation positionsUpflow, downflow, horizontal left, horizontal right
Venting
VentingDirect vent (2-pipe), single-pipe, or ventilated combustion airMaximum equivalent vent length depends on size, pipe diameter and altitude; see installation instructions.
Electrical
Blower motor1/2 HP
Maximum unit amps7.4 A
Maximum fuse / breaker15 A
Electrical supply115 V, 60 Hz, 1 phase (104 – 127 V)
Controls
Burner stagingSingle-stage (full fire on every call)
Other
Burners2
InducerSingle-speed
FuelNatural gas; propane with gas conversion accessory kit

Variants

Sizes that share this model page. A variant gets its own page only when it has substantial independent value.

Carrier Performance 96 single-stage 59SP6B 040V17–12 variants
SizeInput highInput lowOutput highOutput lowAFUE upflowAFUE down/horizWidth (in)Ship wt (lb)Cooling CFMMotor HP
040V17–1240,00039,00096.79517.5134205 – 11051/2
040V14–1040,00039,000969514.19124130 – 9901/2

Filters, serial numbers and service parts

Filter

  • Field-supplied filter; certified watt data uses Carrier media filter 325531-40

Components this family's service documentation covers

  • Hot-surface ignitor
  • Flame sensor
  • Pressure switches
  • Inducer motor
  • Condensate trap and drain components
  • ECM blower motor
  • Control board

Service-parts list source: Components documented for service in 59SP6B-01SI REV B.

Warranty coverage, registered or not

Registered
10-year parts and lifetime limited heat exchanger warranty
Not registered
Default 5-year parts and 20-year heat exchanger limited warranty

As published by the manufacturer. Source. Conditions and exceptions are in the warranty certificate.

Fault codes this model can show

Best for

  • Compact detached houses and larger suites with modest verified design heat loss
  • Buyers who want the Performance tier's blower and controls without two-stage firing
  • Homes with up to about 2.5 tons of cooling on the same ductwork

Compatible controls

  • Standard 24 V thermostat terminals: G, C, W, Y/Y2, Y1, R, DHUM
  • ecobee for Carrier smart thermostat with InteliSense technology (InteliSense capable)
  • On-board 3-digit LCD control display with ComfortFan continuous-fan control

System integrations

  • Air conditioner or heat pump (dual-fuel / Hybrid Heat) with a compatible thermostat
  • Twinning of two furnaces with the accessory kit
  • Field-supplied filter or optional media filter cabinet

Warranty, as published

Default 5-year parts limited warranty and 20-year heat exchanger limited warranty; 10-year parts and lifetime limited heat exchanger warranty with timely registration.

Register within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration. Original purchaser/homeowner only; see the warranty certificate. Source

BC Wide can help with registration and warranty enquiries for furnaces it installs or services. Ask about warranty support.

Manuals, codes and service

This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.

Questions people ask

Why buy the single-stage Performance 96 instead of the two-stage one?

The 59SP6B costs less than the two-stage 59TP6C and shares its blower generation and controls. The trade-off is one gas rate: it fires at full rate on every call, so rooms move a little more on mild days.

What is the difference between the 040V17–12 and the 040V14–10?

Same 40,000 BTU/h input and 39,000 BTU/h output. The 040V14–10 has the narrow 14.2-inch cabinet, slightly lower certified upflow AFUE (96.0% versus 96.7%) and a smaller cooling airflow range.

Considering the 59SP6B 040V17–12?

Get a published ballpark range for a supply-and-install, then a consultation to confirm sizing from a heat-loss assessment. Equipment-only pricing is not offered on this site.

Call Email Estimate