Carrier · Infinity 98 with Greenspeed (59MN7C) · Model

Carrier Infinity 98 59MN7C 100C21–22

The 59MN7C 100C21–22 is the 100,000 BTU/h, 21-inch-wide modulating Infinity 98: input from 40,000 BTU/h minimum to 100,000 BTU/h maximum, 98,000 BTU/h maximum output, certified 97.3% AFUE upflow and horizontal. It serves larger, older houses above the 080 sizes.

CurrentresidentialBC Wide service: confirm by phone

Rating plate

Model
59MN7C 100C21–22
Input
40,000 – 100,000 BTU/h
Output
39,000 – 98,000 BTU/h
AFUE
97.3% upflow · 95% down/horiz
Burner
Modulating
Blower
ECM, constant airflow
Fuel
Natural gas / Propane
Cabinet
35 × 21 × 29.5 in
Canada
Available in Canada
Size designation as printed in Carrier product data 59MN7C-01PD. The complete number on the rating plate adds the voltage and minor-series digits; copy it from the plate when ordering parts.

This size modulates between 40,000 BTU/h minimum input and 100,000 BTU/h maximum input, with Carrier certifying 97.3% AFUE upflow and horizontal and 95.0% downflow. Its certified temperature rise bands run from 35 to 65 °F at minimum fire to 45 to 75 °F at maximum fire, with the intermediate band at 50 to 80 °F.

The 21-inch cabinet carries five burners and a 1 HP communicating constant-airflow blower reaching 2,165 CFM for cooling, enough for a 5.5- to 6-ton coil. It is the only 100,000 BTU/h size in the modulating family, sharing its cabinet with the 080C21–20.

Houses that genuinely calculate to 100,000 BTU/h input are uncommon among newer Lower Mainland homes, and at this capacity the modulating burner's mild-weather low-fire behaviour is the main argument over a two-stage furnace. The size is chosen from the heat-loss calculation; Carrier's product data repeats the standing warning against oversizing.

Specifications

From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.

Carrier Infinity 98 59MN7C 100C21–22 specifications
SpecificationValueNote
Input
Input, maximum heat100,000 BTU/h
Input, intermediate heat65,000 BTU/h
Input, minimum heat40,000 BTU/h
Output
Output capacity, maximum heat98,000 BTU/hCarrier product data; DOE test procedure, position dependent.
Output capacity, intermediate heat54,000 BTU/hPrinted as 54,000 BTU/h in Carrier product data 59MN7C-01PD, which is inconsistent with the 65,000 BTU/h intermediate input published for the same size. Confirm the certified figure from the rating plate before quoting.
Output capacity, minimum heat39,000 BTU/h
Efficiency
AFUE, upflow / horizontal97.3 %
AFUE, downflow95 %
Airflow
Certified temperature rise, maximum heat45 – 75 °F (25 – 42 °C)
Certified temperature rise, intermediate heat50 – 80 °F (28 – 44 °C)
Certified temperature rise, minimum heat35 – 65 °F (19 – 36 °C)
Airflow, maximum heat @ rated ESP1,445 CFM
Airflow, intermediate heat @ rated ESP825 CFM
Airflow, minimum heat @ rated ESP645 CFM
Cooling airflow @ 0.5 in. w.c.2,165 CFM
Cooling capacity match5.5 tons @ 400 CFM/ton; 6 tons @ 350 CFM/ton
Blower motorCommunicating variable-speed, constant-airflow (VCA) ECMMeasures and holds the airflow the control requests.
Physical
Cabinet width21 in533 mm
Approximate shipping weight166 lb75.1 kg
Cabinet height35 in889 mm
Cabinet depth29.5 in
Installation positionsUpflow, downflow, horizontal left, horizontal right
Venting
VentingDirect vent (2-pipe) or ventilated combustion airCarrier product data lists direct-vent and ventilated-combustion-air applications for this family.
Electrical
Blower motor1 HP
Maximum unit amps14.4 A
Maximum fuse / breaker20 A
Electrical supply115 V, 60 Hz, 1 phase (104 – 127 V)
Controls
Burner stagingModulating (variable-capacity gas valve)
Other
Burners5
InducerVariable-speed
FuelNatural gas; propane with gas conversion accessory

Filters, serial numbers and service parts

Filter

  • Field-supplied filter; certified watt data uses Carrier media filter 325531-40

Components this family's service documentation covers

  • Hot-surface ignitor
  • Flame sensor
  • Pressure switches
  • Variable-speed inducer motor
  • Condensate trap and drain components
  • Constant-airflow ECM blower
  • Modulating gas valve
  • Control board

Service-parts list source: Components documented for service in 59MN7C product data and service literature.

Best for

  • Larger and older detached homes with higher verified design heat loss
  • Communicating Infinity systems with 5.5- to 6-ton cooling
  • Buyers who want modulating operation across a wide capacity band

Compatible controls

  • Communicating modulating Infinity system with Infinity Control, Infinity zoning and Infinity cooling
  • 3-digit display showing fault codes and furnace status; Bluetooth and NFC service tools
  • RAT and SAT thermistor connections for temperature rise

System integrations

  • Infinity air conditioner or heat pump (dual-fuel) with communicating control
  • Infinity zoning for single- and multiple-zone systems
  • Field-supplied filter or optional media filter cabinet

Manuals, codes and service

This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.

Questions people ask

What is the minimum firing rate of this furnace?

Carrier publishes a 40,000 BTU/h minimum input (39,000 BTU/h output) against a 100,000 BTU/h maximum, so the burner can run at about 40% of full input on mild days.

The product data lists the intermediate output oddly. What should I trust?

Carrier's 59MN7C-01PD prints 54,000 BTU/h as the intermediate-heat output for this size, which contradicts the 65,000 BTU/h intermediate input and the pattern of every other size in the family (about 97% of input). Confirm the certified figure from the rating plate or Carrier before quoting.

Considering the 59MN7C 100C21–22?

Get a published ballpark range for a supply-and-install, then a consultation to confirm sizing from a heat-loss assessment. Equipment-only pricing is not offered on this site.

Call Email Estimate