GasFurnace.caby BC Wide Heating & Air Conditioning

Carrier · Series

Carrier Infinity 96 (59TN6B)

The Carrier Infinity 96 (59TN6B) is a communicating two-stage condensing furnace with a variable-speed constant-airflow (VCA) ECM blower, rated up to 96.7% AFUE, sold in five sizes from 60,000 to 120,000 BTU/h input. It is the entry point of Carrier's communicating Infinity line.

Series rating plate

Family code
59TN6B
Tier
Infinity
Burner
Two-stage
Blower
ECM, constant airflow
AFUE claim
Up to 96.7% AFUE
Fuel
Natural gas / Propane
Positions
Upflow, Downflow, Horizontal left, Horizontal right
Control
Communicating Infinity control (diagnostics through the Infinity user interface or APM accessory)
Production
Current 59TN6B generation documented from product data edition 04/19.
Status
Current · Available in Canada
Product data 59TN6B-01PD states: "All sizes are design certified in Canada." Listed on Carrier's Canadian residential site as the Infinity 96 (2026-09-07).

The Infinity 96 pairs a two-stage Comfort Heat gas system with Carrier's communicating variable-speed constant-airflow ECM blower: the motor measures and holds the airflow the control requests as filters load and dampers move, instead of running at fixed taps. Because it communicates, it is designed to run with a Carrier Infinity Control and Infinity air conditioner or heat pump as one system, with two-stage cooling, dehumidification and zoning logic handled by the communicating control.

Carrier certifies the five sizes at 96.1% to 96.7% AFUE upflow and horizontal and 95.0% downflow. The family carries Ideal Humidity System technology, Comfort Heat adaptive two-stage control, and SmartEvap coil-drain logic when paired with compatible cooling equipment. It condenses, so every installation needs plastic venting and a condensate drain.

The 59TN6B is the current-generation Infinity 96 in Carrier's Canadian line-up, sitting below the Infinity 97 and the modulating Infinity 98. It shares its marketing name with earlier Infinity 96 generations (including 59TN6A); the family code on the rating plate is what tells them apart, and documentation on this site is kept separate per generation.

Highlights from the manufacturer's product data

  • Two-stage gas valve with two-speed inducer
  • Communicating variable-speed constant-airflow (VCA) ECM blower
  • Up to 96.7% AFUE (upflow and horizontal); 95.0% downflow
  • All sizes meet ENERGY STAR Version 4.1 criteria (95%+ AFUE) per Carrier product data
  • Infinity communicating control; single- and multiple-zone compatible
  • Factory-supplied media filter cabinet on every size

Models in this series

Capacity and width variants documented on this site. Values from the manufacturer's product data; “—” means not published there.

Series variants
SizeInput high (BTU/h)Input low (BTU/h)Output high (BTU/h)AFUE upflow (%)AFUE down/horiz (%)Width (in)Page
060C17–1460,00039,00058,00096.39517.5Model page
080C21–2080,00052,00078,00096.79521Model page
080C17–1480,00052,00078,00096.29517.5Variant
100C21–22100,00065,00098,00096.19521Model page
120C24–22120,00078,000117,00096.79524.5Model page

Venting

Direct vent (two-pipe), single-pipe, or ventilated combustion air (Carrier product data 59TN6B-01PD).

Factory natural gas. Propane convertible with a gas conversion accessory (Carrier product data).

Controls and integrations

  • Communicating Infinity system: designed to run with a Carrier Infinity Control and Infinity air conditioner or heat pump
  • Compatible with single- and multiple-zone Infinity systems
  • Self-diagnostics and extended diagnostic data through the Advanced Product Monitor (APM) accessory or Infinity User Interface

Fault codes for this series

No codes documented yet for this series. See the Carrier index.

Manuals and documents

Questions people ask

What makes the Infinity 96 different from the Performance 96?

The Infinity 96 is a communicating furnace with a constant-airflow ECM blower: it reports and adjusts airflow through the communicating control and integrates with Infinity cooling and zoning. The Performance 96 is non-communicating. Both are two-stage 95%+ condensing furnaces.

Can the Infinity 96 run without an Infinity Control?

Carrier's product data describes the Infinity 96 as part of a complete Infinity System with an Infinity Control and Infinity cooling equipment. Ask how the furnace will be controlled in your installation; thermostat compatibility is part of the system design.

Is the Infinity 96 still sold in Canada?

Carrier's Canadian site lists the Infinity 96 (59TN6) as a current family and the 59TN6B product data states all sizes are design certified in Canada. Availability of a specific size is confirmed with the dealer.

Talk it through before you decide