GasFurnace.caby BC Wide Heating & Air Conditioning

Carrier · Performance 96 single-stage (59SP6B) · Model

Carrier Performance 96 single-stage 59SP6B 080V21–20

The 59SP6B 080V21–20 is the 80,000 BTU/h, 21-inch-wide single-stage Performance 96: 78,000 BTU/h output at one gas rate, 97.0% AFUE upflow, with a 1 HP variable-speed ECM blower. It serves larger detached houses whose heat-loss calculation supports the capacity.

CurrentresidentialBC Wide service: confirm by phone

Rating plate

Model
59SP6B 080V21–20
Input
undefined – 80,000 BTU/h
Output
undefined – 78,000 BTU/h
AFUE
97% upflow · 95% down/horiz
Burner
Single-stage
Blower
ECM, constant torque (variable-speed)
Fuel
Natural gas / Propane
Cabinet
35 × 21 × 29.5 in
Canada
Available in Canada
Size designation as printed in Carrier product data 59SP6B-01PD. The complete number on the rating plate adds the voltage and minor-series digits; copy it from the plate when ordering parts.

At 80,000 BTU/h input, the single-stage Performance 96 is a full-fire machine: 78,000 BTU/h out on every call until the thermostat is satisfied. Carrier certifies 97.0% AFUE upflow and 95% downflow and horizontal for this size, tying the family's best upflow figure.

The 21-inch cabinet and 1 HP variable 25-speed ECM blower reach 2,110 CFM for cooling, which is why this width is chosen when a 4- to 5-ton air conditioner or heat pump shares the ductwork. The 17.5-inch sibling (080V17–16) delivers the same 78,000 BTU/h with a 3/4 HP blower at the same 97.0% upflow.

For houses that spend most of the heating season needing far less than full fire, the two-stage Performance 96 at the same capacity runs gentler, low-fire cycles; the single-stage version trades that comfort for a lower first cost. The comparison belongs in the proposal, and the size itself belongs to the heat-loss calculation.

Specifications

From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.

Carrier Performance 96 single-stage 59SP6B 080V21–20 specifications
SpecificationValueNote
Input
Input80,000 BTU/h
Output
Output capacity78,000 BTU/hCarrier product data; DOE test procedure, position dependent.
Efficiency
AFUE, upflow97 %
AFUE, downflow / horizontal95 %
Airflow
Airflow, heating @ rated ESP1,315 CFM
Cooling airflow range270 – 2110 CFM
Cooling capacity match5 tons @ 400 CFM/ton; 5.5 tons @ 350 CFM/ton
Blower motorVariable 25-speed, constant-torque (VCT) ECMNot a constant-airflow motor; it does not report airflow to the control.
Certified temperature rise range40 – 70 °F (22 – 39 °C)
Physical
Cabinet width21 in533 mm
Shipping weight161 lb73.0 kg
Cabinet height35 in889 mm
Cabinet depth29.5 in750 mm
Installation positionsUpflow, downflow, horizontal left, horizontal right
Venting
VentingDirect vent (2-pipe), single-pipe, or ventilated combustion airMaximum equivalent vent length depends on size, pipe diameter and altitude; see installation instructions.
Electrical
Blower motor1 HP
Maximum unit amps13.1 A
Maximum fuse / breaker20 A
Electrical supply115 V, 60 Hz, 1 phase (104 – 127 V)
Controls
Burner stagingSingle-stage (full fire on every call)
Other
Burners4
InducerSingle-speed
FuelNatural gas; propane with gas conversion accessory kit

Variants

Sizes that share this model page. A variant gets its own page only when it has substantial independent value.

Carrier Performance 96 single-stage 59SP6B 080V21–20 variants
SizeInput highInput lowOutput highOutput lowAFUE upflowAFUE down/horizWidth (in)Ship wt (lb)Cooling CFMMotor HP
080V21–2080,00078,000979521161270 – 21101
080V17–1680,00078,000979517.5151255 – 16253/4

Filters, serial numbers and service parts

Filter

  • Field-supplied filter; certified watt data uses Carrier media filter 325531-40

Components this family's service documentation covers

  • Hot-surface ignitor
  • Flame sensor
  • Pressure switches
  • Inducer motor
  • Condensate trap and drain components
  • ECM blower motor
  • Control board

Service-parts list source: Components documented for service in 59SP6B-01SI REV B.

Warranty coverage, registered or not

Registered
10-year parts and lifetime limited heat exchanger warranty
Not registered
Default 5-year parts and 20-year heat exchanger limited warranty

As published by the manufacturer. Source. Conditions and exceptions are in the warranty certificate.

Fault codes this model can show

Best for

  • Larger detached homes whose heat-loss calculation supports 78,000 BTU/h of output
  • Houses with a 4- to 5-ton air conditioner or heat pump on shared ductwork
  • Budget-conscious replacements where full-fire cycles are acceptable

Compatible controls

  • Standard 24 V thermostat terminals: G, C, W, Y/Y2, Y1, R, DHUM
  • ecobee for Carrier smart thermostat with InteliSense technology (InteliSense capable)
  • On-board 3-digit LCD control display with ComfortFan continuous-fan control

System integrations

  • Air conditioner or heat pump (dual-fuel / Hybrid Heat) with a compatible thermostat
  • Twinning of two furnaces with the accessory kit
  • Field-supplied filter or optional media filter cabinet

Warranty, as published

Default 5-year parts limited warranty and 20-year heat exchanger limited warranty; 10-year parts and lifetime limited heat exchanger warranty with timely registration.

Register within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration. Original purchaser/homeowner only; see the warranty certificate. Source

BC Wide can help with registration and warranty enquiries for furnaces it installs or services. Ask about warranty support.

Manuals, codes and service

This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.

Questions people ask

Is 80,000 BTU/h input too big for a modern house?

For many modern houses, yes; for larger or older ones, no. The heat-loss calculation decides. Carrier's own product data warns that excessive oversizing can shorten furnace and vent life.

What is the difference between the 080V21–20 and the 080V17–16?

Same input and output and the same 97.0% upflow AFUE. The 080V21–20 has the wider 21-inch cabinet, a 1 HP blower with up to 2,110 CFM of cooling airflow, and a 20 A breaker; the 17.5-inch unit uses a 3/4 HP blower and 15 A.

Considering the 59SP6B 080V21–20?

Get a published ballpark range for a supply-and-install, then a consultation to confirm sizing from a heat-loss assessment. Equipment-only pricing is not offered on this site.

Call Email Estimate