GasFurnace.caby BC Wide Heating & Air Conditioning

Carrier · Status code

Carrier 59TP7A status code 46.1: momentary loss of power

Status code 46.1 records that the control saw its power drop and return. The furnace control keeps the last seven faults in memory for 72 hours of powered operation, so a brief interruption such as a blip on the electrical service is logged as 46.1.

Informationnumeric

On the control

Code
46
Minor
46.1
Door LED
4 short flashes then 6 long
Controller
59TP7A integrated furnace control with 3-digit LCD display and door LED
Applies to
Carrier Performance 97 (59TP7A)
Carrier's service label: major code shown on the door LED as short flashes for the first digit and long flashes for the second digit, so 46 is 4 short, 6 long.

What each minor code says, verbatim

Sub-codes for Carrier code 46
DisplayManufacturer wording
46.1Momentary loss of power

A code is a condition, not a diagnosis

46.1 is a record of an event, not a fault in the furnace. It matters mainly when it repeats often, which points at the electrical supply: a loose connection, a failing breaker or disconnect, or neighbourhood power dips. The stored fault history distinguishes a one-time blip from a pattern.

Which furnaces this applies to

Documented for Carrier 59TP7A furnaces (all nine sizes) in installation instructions 59TP7A-01SI REV A, edition 06/23. It is the same control behaviour that runs the 90-second blower-only recovery (code 12.1) when the thermostat is calling at power-up.

Scope: Carrier 59TP7A Performance 97 furnaces with the on-board 3-digit display control. Not sure which control you have? Send us the full model number from the rating plate.

Safe things to look at first

  • Read the full code on the control display through the door, including any minor digit (for example 33.2), and write it down.
  • Look, without touching, for obvious conditions you can report: snow or ice at the vent terminations, water on the floor, a loaded filter, a condensate pump that is full or off.
  • Note whether the furnace still heats at all, and how long it runs before the code returns.
  • Note whether the code appears after known power blips or outages.
  • If the furnace restarts and heats normally, nothing further is needed for a single occurrence.

Do not

  • Do not bypass or jumper the door switch, limit switches, rollout switches or pressure switches.
  • Do not open the burner compartment, disconnect tubing, or adjust the gas valve or gas pressure.
  • Do not keep cycling power to force the furnace to relight; repeated resets hide the fault and can allow unburned gas to build up after ignition failures. If the code returns, stop and call.

Homeowner-safe checks (look and read only)

  • Note whether the code follows a known power blip or outage

When to call a technician

  • If the code repeats often, the electrical supply should be checked

What a technician does

  • A technician reviews the stored fault history to see how often power events occur and, when they are frequent, checks the supply connections, breaker and disconnect.

Questions people ask

My furnace shows 46.1 after a power outage. Is it damaged?

No. It logged that the power dropped and returned, which is exactly what happened. If it heats normally through a cycle, no repair is needed.

Why does 46.1 keep appearing every week?

Repeated power events usually come from the supply side: a loose connection, an overloaded or failing breaker, or utility dips. Have the supply checked before blaming the furnace.

Seeing code 46 on your Carrier?

Tell us the full code, the model number and whether the furnace still heats on low. BC Wide prioritizes no-heat calls across Greater Vancouver.

Call Email Estimate