Carrier · Performance 96 (59TP6C) · Model
Carrier Performance 96 59TP6C 100V21–20
The 59TP6C 100V21–20 is the 100,000 BTU/h, 21-inch-wide Performance 96: 65,000 BTU/h on low fire, 97,000 BTU/h output on high, 96.1% AFUE upflow, with a 1 HP blower that can carry a 5-ton air conditioner or heat pump. It belongs in larger, leakier or older houses whose heat-loss calculation lands above what the 080 size can serve.
Rating plate
- Model
- 59TP6C 100V21–20
- Input
- 65,000 – 100,000 BTU/h
- Output
- 63,000 – 97,000 BTU/h
- AFUE
- 96.1% upflow · 95% down/horiz
- Burner
- Two-stage
- Blower
- ECM, constant torque (variable-speed)
- Fuel
- Natural gas / Propane
- Cabinet
- 35 × 21 × 29.5 in
- Canada
- Available in Canada
Low fire is 65,000 BTU/h input and 63,000 BTU/h output; high fire is 100,000 BTU/h input and 97,000 BTU/h output. This is the size a 1960s or 1970s house with original windows, little insulation and a big open layout may land on after a heat-loss calculation, and it is also the size that shows up in retrofit jobs where an old 120,000 BTU/h furnace proved genuinely undersized for the ductwork and the house.
The 1 HP blower moves 1,715 CFM in high heat at rated static pressure and up to 2,170 CFM for cooling, enough for a 5-ton coil at 400 CFM per ton. The 100V21–22 sibling in the same 21-inch cabinet adds an extended airflow profile (525 to 2,250 CFM, certified 96.2% upflow) and is the choice when maximum cooling airflow matters more than anything else in this width.
Oversizing is the trap with 100,000 BTU/h inputs. Carrier's product data repeats the warning that excessive oversizing can shorten furnace and vent life, and its sizing note says none of the sizes may be used where the heating load is 20,000 BTU/h or lower. A house that needs 100,000 BTU/h input is uncommon among newer Lower Mainland homes; when the old furnace was 120,000 BTU/h and the house has since been insulated, the calculation usually comes back smaller.
Specifications
From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, high heat | 100,000 BTU/h | |
| Input, low heat | 65,000 BTU/h | |
| Output | ||
| Output capacity, high heat | 97,000 BTU/h | Carrier product data; DOE test procedure, position dependent. |
| Output capacity, low heat | 63,000 BTU/h | |
| Efficiency | ||
| AFUE, upflow | 96.1 % | |
| AFUE, downflow / horizontal | 95 % | |
| Airflow | ||
| Airflow, high heat @ rated ESP | 1,715 CFM | |
| Airflow, low heat @ rated ESP | 1,425 CFM | |
| Cooling airflow range | 340 – 2170 CFM | |
| Cooling capacity match | 5 tons @ 400 CFM/ton; 5.5 tons @ 350 CFM/ton | |
| Blower motor | Variable 25-speed, constant-torque (VCT) ECM | Not a constant-airflow motor; it does not report airflow to the control. |
| Certified temperature rise, high heat | 40 – 70 °F (22 – 39 °C) | |
| Certified temperature rise, low heat | 30 – 60 °F (17 – 33 °C) | |
| Physical | ||
| Cabinet width | 21 in | 533 mm |
| Shipping weight | 172 lb | 78.0 kg |
| Cabinet height | 35 in | 889 mm |
| Cabinet depth | 29.5 in | 750 mm |
| Installation positions | Upflow, downflow, horizontal left, horizontal right | |
| Venting | ||
| Venting | Direct vent (2-pipe), single-pipe, or ventilated combustion air; 2-in., 3-in. or optional 4-in. termination | Maximum equivalent vent length depends on size, pipe diameter and altitude; see installation instructions. |
| Electrical | ||
| Blower motor | 1 HP | |
| Maximum unit amps | 13.2 A | |
| Maximum fuse / breaker | 20 A | |
| Electrical supply | 115 V, 60 Hz, 1 phase (104 – 127 V) | |
| Controls | ||
| Burner staging | Two-stage (low and high fire) | |
| Other | ||
| Inducer | Two-speed | |
| Fuel | Natural gas; propane with CSA-listed conversion kit | |
Variants
Sizes that share this model page. A variant gets its own page only when it has substantial independent value.
| Size | Input high | Input low | Output high | Output low | AFUE upflow | AFUE down/horiz | Width (in) | Ship wt (lb) | Cooling CFM | Motor HP |
|---|---|---|---|---|---|---|---|---|---|---|
| 100V21–20 | 100,000 | 65,000 | 97,000 | 63,000 | 96.1 | 95 | 21 | 172 | 340 – 2170 | 1 |
| 100V21–22 | 100,000 | 65,000 | 97,000 | 63,000 | 96.2 | 95 | 21 | 173 | 525 – 2250 | 1 |
Filters, serial numbers and service parts
Filter
- Field-supplied filter; certified watt data uses Carrier media filter 325531-40
Components this family's service documentation covers
- Hot-surface ignitor
- Flame sensor
- Pressure switches (LPS/HPS)
- Inducer motor
- Condensate trap and drain components
- ECM blower motor
- Control board
Service-parts list source: Components documented for service in 59TP6C-01SI (edition 06/23).
Warranty coverage, registered or not
- Registered
- 10-year parts and lifetime limited heat exchanger warranty
- Not registered
- Default 5-year parts and 20-year heat exchanger limited warranty
As published by the manufacturer. Source. Conditions and exceptions are in the warranty certificate.
Fault codes this model can show
Best for
- Larger and older detached homes with higher design heat loss
- Houses with a 4- to 5-ton air conditioner or heat pump on shared ductwork
- Retrofits where the heat-loss calculation confirms the house genuinely needs the capacity
Compatible controls
- Standard 24 V thermostat terminals: G, C, W, Y/Y2, Y1, R, DHUM
- ecobee for Carrier smart thermostat with InteliSense technology (InteliSense capable)
- On-board 3-digit LCD control display for set-up, diagnostics and fault history
System integrations
- Air conditioner or heat pump (dual-fuel / Hybrid Heat) with a compatible thermostat
- Twinning of two furnaces with the accessory kit
- Field-supplied filter or optional media filter cabinet
Warranty, as published
Default 5-year parts and 20-year heat exchanger limited warranties; 10-year parts and lifetime limited heat exchanger warranty with timely registration.
Register within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration. Original purchaser/homeowner only; see the warranty certificate. Source
BC Wide can help with registration and warranty enquiries for furnaces it installs or services. Ask about warranty support.
Manuals, codes and service
Documents
Fault codes that apply
- Code 31: high-heat pressure switch (HPS) open or slow to close
- Code 10: rapid flash - L1 polarity fault
- Code 12: W on at power up
- Code 13: limit lockout or ignition lockout
- Code 14: flame-loss lockouts during a heat request
- Code 15: lockout - no blower rpms detected
- Code 19: InteliSense communications loss
- Code 21: 24 VAC sensed on the gas valve when it shouldn't be
- Code 22: false flame
- Code 23: pressure switch stuck closed
- Code 24: fuse fault
- Code 25: control program and configuration faults
- Code 27: super plug or control program fault
- Code 32: open main pressure switch (LPS)
- Code 33: limit circuit, high-heat or ignition lockout
- Code 34: flame lost after ignition
- Code 41: blower RPM not detected
- Code 43: HPS closed before LPS
- Code 45: control failure
- Code 46: momentary loss of power
- Code 52: supply-air temperature sensor open or short
- Code 53: return-air temperature sensor open or short
BC Wide service
This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.
Questions people ask
When is 100,000 BTU/h actually needed in the Lower Mainland?
Only when a heat-loss calculation says so. Mild Vancouver winters mean many detached homes calculate well below 80,000 BTU/h; the 100,000 BTU/h sizes serve the minority of larger, older or poorly insulated houses. Ask for the number before accepting any size.
What is the difference between the 100V21–20 and the 100V21–22?
Same gas inputs and outputs in the same 21-inch cabinet. The 100V21–22 has the extended airflow blower profile (up to 2,250 CFM for cooling versus 2,170 CFM), 96.2% instead of 96.1% AFUE upflow, and a slightly different electrical draw. It is 1 lb heavier.
Does this size need a 20-amp circuit?
Carrier lists a maximum fuse or circuit breaker of 20 A and 12 AWG minimum wire for the 100V21–20 by default. The 120,000 BTU/h unit offers an optional low-amp kit; confirm with the electrician on site.