GasFurnace.caby BC Wide Heating & Air Conditioning

Carrier · Infinity 96 (59TN6B) · Model

Carrier Infinity 96 59TN6B 060C17–14

The 59TN6B 060C17–14 is the 60,000 BTU/h size of Carrier's communicating Infinity 96: 39,000 BTU/h on low fire, 58,000 BTU/h output on high, 96.3% AFUE upflow and horizontal, with a 1/2 HP constant-airflow ECM blower. It is the smallest Infinity 96 and the entry size of the communicating line.

CurrentresidentialBC Wide service: confirm by phone

Rating plate

Model
59TN6B 060C17–14
Input
39,000 – 60,000 BTU/h
Output
38,000 – 58,000 BTU/h
AFUE
96.3% upflow · 95% down/horiz
Burner
Two-stage
Blower
ECM, constant airflow
Fuel
Natural gas / Propane
Cabinet
35 × 17.5 × 30 in
Canada
Available in Canada
Size designation as printed in Carrier product data 59TN6B-01PD. The complete number on the rating plate adds the voltage and minor-series digits; copy it from the plate when ordering parts.

The smallest Infinity 96 runs the same communicating two-stage system as the larger sizes: 39,000 BTU/h input and 38,000 BTU/h output on low fire, 60,000 BTU/h input and 58,000 BTU/h output on high. Carrier certifies it at 96.3% AFUE upflow and horizontal and 95.0% downflow, with a certified high-heat temperature rise of 35 to 65 °F.

The constant-airflow (VCA) blower is what separates this furnace from the Performance line: through the communicating control it measures and holds the airflow the system requests, so a loaded filter or closed damper is compensated rather than silently starving the heat exchanger. The furnace ships with a factory-supplied 16-inch media filter cabinet.

At 60,000 BTU/h input this size suits compact detached houses and larger suites whose heat-loss calculation supports it. Carrier's product data repeats the family sizing rule: none of the sizes may be used where the heating load is 20,000 BTU/h or lower, and excessive oversizing can shorten furnace and vent life.

Specifications

From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.

Carrier Infinity 96 59TN6B 060C17–14 specifications
SpecificationValueNote
Input
Input, high heat60,000 BTU/h
Input, low heat39,000 BTU/h
Output
Output capacity, high heat58,000 BTU/hCarrier product data; DOE test procedure, position dependent.
Output capacity, low heat38,000 BTU/h
Efficiency
AFUE, upflow / horizontal96.3 %
AFUE, downflow95 %
Airflow
Certified temperature rise, high heat35 – 65 °F (19 – 36 °C)
Certified temperature rise, low heat30 – 60 °F (17 – 33 °C)
Airflow, high heat @ rated ESP1,055 CFM
Airflow, low heat @ rated ESP755 CFM
Cooling airflow range @ 0.5 in. w.c.530 – 1280 CFM
Cooling capacity match3 tons @ 400 CFM/ton; 3.5 tons @ 350 CFM/ton
Blower motorCommunicating variable-speed, constant-airflow (VCA) ECMMeasures and holds the airflow the control requests.
Physical
Cabinet width17.5 in445 mm
Cabinet depth30 in
Approximate shipping weight151 lb68.5 kg
Cabinet height35 in889 mm
Installation positionsUpflow, downflow, horizontal left, horizontal right
Venting
VentingDirect vent (2-pipe), single-pipe, or ventilated combustion airMaximum equivalent vent length depends on size, pipe diameter and altitude; see installation instructions.
Electrical
Blower motor1/2 HP
Maximum input amps9.3 A
Maximum fuse / breaker15 A
Electrical supply115 V, 60 Hz, 1 phase (104 – 127 V)
Controls
Burner stagingTwo-stage (low and high fire)
Other
Burners3
Factory-supplied media cabinet16 in (406 mm)
InducerTwo-speed
FuelNatural gas; propane with gas conversion accessory kit

Filters, serial numbers and service parts

Components this family's service documentation covers

  • Hot-surface ignitor
  • Flame sensor
  • Pressure switches
  • Inducer motor
  • Condensate trap and drain components
  • Constant-airflow ECM blower
  • Control board

Service-parts list source: Components documented for service in 59TN6B product data and service literature.

Best for

  • Compact detached houses and larger suites with modest verified design heat loss
  • Homes building a communicating Infinity system with an Infinity Control and Infinity cooling
  • Buyers who want constant-airflow blower behaviour at the entry of the Infinity line

Compatible controls

  • Communicating Infinity system with Infinity Control, Infinity air conditioner or heat pump
  • Compatible with single- and multiple-zone Infinity systems
  • Self-diagnostics and extended diagnostic data through the Advanced Product Monitor (APM) accessory or Infinity User Interface

System integrations

  • Infinity air conditioner or heat pump (dual-fuel) with communicating control
  • Infinity zoning for single- and multiple-zone systems
  • Factory-supplied external media filter cabinet

Manuals, codes and service

This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.

Questions people ask

Why is the Infinity 96's blower different from the Performance 96's?

The Infinity 96 uses a communicating constant-airflow (VCA) ECM motor that measures and holds the requested airflow; the Performance 96's constant-torque motor runs at selected speeds without airflow feedback. The Infinity motor is part of the communicating system design.

Does the 060C17–14 need an Infinity Control?

The furnace is designed to run as part of a communicating Infinity System with an Infinity Control and Infinity cooling. Confirm the control configuration with the installer before purchase.

Considering the 59TN6B 060C17–14?

Get a published ballpark range for a supply-and-install, then a consultation to confirm sizing from a heat-loss assessment. Equipment-only pricing is not offered on this site.