Carrier · Infinity 96 (59TN6B) · Model
Carrier Infinity 96 59TN6B 060C17–14
The 59TN6B 060C17–14 is the 60,000 BTU/h size of Carrier's communicating Infinity 96: 39,000 BTU/h on low fire, 58,000 BTU/h output on high, 96.3% AFUE upflow and horizontal, with a 1/2 HP constant-airflow ECM blower. It is the smallest Infinity 96 and the entry size of the communicating line.
Rating plate
- Model
- 59TN6B 060C17–14
- Input
- 39,000 – 60,000 BTU/h
- Output
- 38,000 – 58,000 BTU/h
- AFUE
- 96.3% upflow · 95% down/horiz
- Burner
- Two-stage
- Blower
- ECM, constant airflow
- Fuel
- Natural gas / Propane
- Cabinet
- 35 × 17.5 × 30 in
- Canada
- Available in Canada
The smallest Infinity 96 runs the same communicating two-stage system as the larger sizes: 39,000 BTU/h input and 38,000 BTU/h output on low fire, 60,000 BTU/h input and 58,000 BTU/h output on high. Carrier certifies it at 96.3% AFUE upflow and horizontal and 95.0% downflow, with a certified high-heat temperature rise of 35 to 65 °F.
The constant-airflow (VCA) blower is what separates this furnace from the Performance line: through the communicating control it measures and holds the airflow the system requests, so a loaded filter or closed damper is compensated rather than silently starving the heat exchanger. The furnace ships with a factory-supplied 16-inch media filter cabinet.
At 60,000 BTU/h input this size suits compact detached houses and larger suites whose heat-loss calculation supports it. Carrier's product data repeats the family sizing rule: none of the sizes may be used where the heating load is 20,000 BTU/h or lower, and excessive oversizing can shorten furnace and vent life.
Specifications
From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, high heat | 60,000 BTU/h | |
| Input, low heat | 39,000 BTU/h | |
| Output | ||
| Output capacity, high heat | 58,000 BTU/h | Carrier product data; DOE test procedure, position dependent. |
| Output capacity, low heat | 38,000 BTU/h | |
| Efficiency | ||
| AFUE, upflow / horizontal | 96.3 % | |
| AFUE, downflow | 95 % | |
| Airflow | ||
| Certified temperature rise, high heat | 35 – 65 °F (19 – 36 °C) | |
| Certified temperature rise, low heat | 30 – 60 °F (17 – 33 °C) | |
| Airflow, high heat @ rated ESP | 1,055 CFM | |
| Airflow, low heat @ rated ESP | 755 CFM | |
| Cooling airflow range @ 0.5 in. w.c. | 530 – 1280 CFM | |
| Cooling capacity match | 3 tons @ 400 CFM/ton; 3.5 tons @ 350 CFM/ton | |
| Blower motor | Communicating variable-speed, constant-airflow (VCA) ECM | Measures and holds the airflow the control requests. |
| Physical | ||
| Cabinet width | 17.5 in | 445 mm |
| Cabinet depth | 30 in | |
| Approximate shipping weight | 151 lb | 68.5 kg |
| Cabinet height | 35 in | 889 mm |
| Installation positions | Upflow, downflow, horizontal left, horizontal right | |
| Venting | ||
| Venting | Direct vent (2-pipe), single-pipe, or ventilated combustion air | Maximum equivalent vent length depends on size, pipe diameter and altitude; see installation instructions. |
| Electrical | ||
| Blower motor | 1/2 HP | |
| Maximum input amps | 9.3 A | |
| Maximum fuse / breaker | 15 A | |
| Electrical supply | 115 V, 60 Hz, 1 phase (104 – 127 V) | |
| Controls | ||
| Burner staging | Two-stage (low and high fire) | |
| Other | ||
| Burners | 3 | |
| Factory-supplied media cabinet | 16 in (406 mm) | |
| Inducer | Two-speed | |
| Fuel | Natural gas; propane with gas conversion accessory kit | |
Filters, serial numbers and service parts
Components this family's service documentation covers
- Hot-surface ignitor
- Flame sensor
- Pressure switches
- Inducer motor
- Condensate trap and drain components
- Constant-airflow ECM blower
- Control board
Service-parts list source: Components documented for service in 59TN6B product data and service literature.
Best for
- Compact detached houses and larger suites with modest verified design heat loss
- Homes building a communicating Infinity system with an Infinity Control and Infinity cooling
- Buyers who want constant-airflow blower behaviour at the entry of the Infinity line
Compatible controls
- Communicating Infinity system with Infinity Control, Infinity air conditioner or heat pump
- Compatible with single- and multiple-zone Infinity systems
- Self-diagnostics and extended diagnostic data through the Advanced Product Monitor (APM) accessory or Infinity User Interface
System integrations
- Infinity air conditioner or heat pump (dual-fuel) with communicating control
- Infinity zoning for single- and multiple-zone systems
- Factory-supplied external media filter cabinet
Manuals, codes and service
Documents
Fault codes that apply
None documented yet.
BC Wide service
This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.
Questions people ask
Why is the Infinity 96's blower different from the Performance 96's?
The Infinity 96 uses a communicating constant-airflow (VCA) ECM motor that measures and holds the requested airflow; the Performance 96's constant-torque motor runs at selected speeds without airflow feedback. The Infinity motor is part of the communicating system design.
Does the 060C17–14 need an Infinity Control?
The furnace is designed to run as part of a communicating Infinity System with an Infinity Control and Infinity cooling. Confirm the control configuration with the installer before purchase.
Considering the 59TN6B 060C17–14?