Carrier 59TP7A status code 43.1: HPS closed before LPS

Status code 43.1 means the high-heat (secondary) pressure switch HPS closed before the low-heat (main) pressure switch LPS during the start-up sequence. On the 59TP7A the control expects the main switch to prove draft first; the secondary switch closing out of sequence is reported as 43.1.

Needs attentionnumeric

On the control

Code
43
Minor
43.1
Door LED
4 short flashes then 3 long
Controller
59TP7A integrated furnace control with 3-digit LCD display and door LED
Applies to
Carrier Performance 97 (59TP7A)
Carrier's service label: major code shown on the door LED as short flashes for the first digit and long flashes for the second digit, so 43 is 4 short, 3 long.

What each minor code says, verbatim

Sub-codes for Carrier code 43
DisplayManufacturer wording
43.1HPS closed before LPS

A code is a condition, not a diagnosis

An out-of-sequence switch reading usually means a hose or port problem: the HPS hose connected to the wrong port, a blocked LPS port or hose, water in one sensing line, or a switch whose set-point does not match the family. The switches and their hoses are tested with a manometer; the sequence is verified across a full start-up before anything is replaced.

Which furnaces this applies to

Documented for Carrier 59TP7A furnaces (all nine sizes) in installation instructions 59TP7A-01SI REV A, edition 06/23. The pressure switches are labelled COLLECTOR BOX-LPS and HOUSING-HPS; each has its nominal break point printed on the switch label.

Scope: Carrier 59TP7A Performance 97 furnaces with the on-board 3-digit display control. Not sure which control you have? Send us the full model number from the rating plate.

Safe things to look at first

  • Read the full code on the control display through the door, including any minor digit (for example 33.2), and write it down.
  • Look, without touching, for obvious conditions you can report: snow or ice at the vent terminations, water on the floor, a loaded filter, a condensate pump that is full or off.
  • Note whether the furnace still heats at all, and how long it runs before the code returns.
  • Note whether the code appears every call or only after service work on the furnace.
  • Check the floor for water and the vent terminations for blockage.

Do not

  • Do not bypass or jumper the door switch, limit switches, rollout switches or pressure switches.
  • Do not open the burner compartment, disconnect tubing, or adjust the gas valve or gas pressure.
  • Do not keep cycling power to force the furnace to relight; repeated resets hide the fault and can allow unburned gas to build up after ignition failures. If the code returns, stop and call.

Homeowner-safe checks (look and read only)

  • Note whether the code appears every call or only after service work
  • Check the floor around the furnace for water

When to call a technician

  • If the furnace is not heating

What a technician does

  • A technician verifies the hose routing against the installation instructions, tests both switches with a manometer against their printed set-points, and confirms the correct start-up sequence before clearing the fault.

Related components and symptoms

Questions people ask

I just had service done and now 43.1 shows. What happened?

A hose reconnected to the wrong port or a trap reinstalled incorrectly is a common cause of out-of-sequence switch readings after service. Ask the technician to verify the hose routing first.