GasFurnace.caby BC Wide Heating & Air Conditioning

Carrier · Performance 96 (59TP6C) · Model

Carrier Performance 96 59TP6C 120V24–22

The 59TP6C 120V24–22 is the largest Performance 96: 120,000 BTU/h input, 78,000 BTU/h on low fire, 117,000 BTU/h output on high, 96.7% AFUE upflow, in a 24.5-inch cabinet with six burners. It is a specialist size for genuinely large or poorly insulated houses, and for duct systems designed around a big furnace.

CurrentresidentialBC Wide service: confirm by phone

Rating plate

Model
59TP6C 120V24–22
Input
78,000 – 120,000 BTU/h
Output
76,000 – 117,000 BTU/h
AFUE
96.7% upflow · 95% down/horiz
Burner
Two-stage
Blower
ECM, constant torque (variable-speed)
Fuel
Natural gas / Propane
Cabinet
35 × 24.5 × 29.5 in
Canada
Available in Canada
Size designation as printed in Carrier product data 59TP6C-01PD. The complete 16-character number on the rating plate adds the voltage and minor-series digits; copy it from the plate when ordering parts.

This is the top of the 59TP6C family, sharing the family's best certified upflow figure of 96.7% with the 080V21–20. Low fire alone delivers 76,000 BTU/h of output, which exceeds the high-fire output of the family's 060 size; high fire delivers 117,000 BTU/h from 120,000 BTU/h of input. The 1 HP blower reaches 2,045 CFM in high heat and up to 2,130 CFM for cooling at rated static pressure.

A 120,000 BTU/h input furnace is a large appliance: 24.5 inches wide, 191 lb, six burners, and a 20 A circuit by default (a low-amp kit drops the draw to 11.3 A and the breaker to 15 A with 14 AWG wire). The cabinet needs a mechanical room that can take it, and the duct system must actually move 2,000+ CFM or the furnace will trip its limits. Carrier's product data is explicit that oversizing can cause premature furnace and vent failure, and none of its sizes is certified for loads of 20,000 BTU/h or below.

In the Lower Mainland this size is uncommon in new work. It most often appears replacing an old 120,000 BTU/h unit in a large older house where the heat-loss calculation genuinely supports it, or where the ductwork and existing layout leave no practical smaller option. BC Wide sizes from the calculation and does not match the old furnace out of habit.

Specifications

From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.

Carrier Performance 96 59TP6C 120V24–22 specifications
SpecificationValueNote
Input
Input, high heat120,000 BTU/h
Input, low heat78,000 BTU/h
Output
Output capacity, high heat117,000 BTU/hCarrier product data; DOE test procedure, position dependent.
Output capacity, low heat76,000 BTU/h
Efficiency
AFUE, upflow96.7 %
AFUE, downflow / horizontal95 %
Airflow
Airflow, high heat @ rated ESP2,045 CFM
Airflow, low heat @ rated ESP1,555 CFM
Cooling airflow range165 – 2130 CFM
Cooling capacity match5 tons @ 400 CFM/ton; 6 tons @ 350 CFM/ton
Blower motorVariable 25-speed, constant-torque (VCT) ECMNot a constant-airflow motor; it does not report airflow to the control.
Certified temperature rise, high heat40 – 70 °F (22 – 39 °C)
Certified temperature rise, low heat30 – 60 °F (17 – 33 °C)
Physical
Cabinet width24.5 in622 mm
Shipping weight191 lb86.6 kg
Cabinet height35 in889 mm
Cabinet depth29.5 in750 mm
Installation positionsUpflow, downflow, horizontal left, horizontal right
Venting
VentingDirect vent (2-pipe), single-pipe, or ventilated combustion air; 2-in., 3-in. or optional 4-in. terminationMaximum equivalent vent length depends on size, pipe diameter and altitude; see installation instructions.
Electrical
Blower motor1 HP
Maximum unit amps12.6 A11.3 A with the optional low-amp kit
Maximum fuse / breaker20 A15 A with the optional low-amp kit (14 AWG minimum wire)
Electrical supply115 V, 60 Hz, 1 phase (104 – 127 V)
Controls
Burner stagingTwo-stage (low and high fire)
Other
InducerTwo-speed
FuelNatural gas; propane with CSA-listed conversion kit

Filters, serial numbers and service parts

Filter

  • Field-supplied filter; certified watt data uses Carrier media filter 325531-40

Components this family's service documentation covers

  • Hot-surface ignitor
  • Flame sensor
  • Pressure switches (LPS/HPS)
  • Inducer motor
  • Condensate trap and drain components
  • ECM blower motor
  • Control board

Service-parts list source: Components documented for service in 59TP6C-01SI (edition 06/23).

Warranty coverage, registered or not

Registered
10-year parts and lifetime limited heat exchanger warranty
Not registered
Default 5-year parts and 20-year heat exchanger limited warranty

As published by the manufacturer. Source. Conditions and exceptions are in the warranty certificate.

Fault codes this model can show

Best for

  • Large detached houses and older homes with high verified design heat loss
  • Houses whose duct system is built to move 2,000+ CFM and can take a 24.5-inch cabinet
  • Replacements where the heat-loss calculation confirms capacity above the 100,000 BTU/h sizes

Compatible controls

  • Standard 24 V thermostat terminals: G, C, W, Y/Y2, Y1, R, DHUM
  • ecobee for Carrier smart thermostat with InteliSense technology (InteliSense capable)
  • On-board 3-digit LCD control display for set-up, diagnostics and fault history

System integrations

  • Air conditioner or heat pump (dual-fuel / Hybrid Heat) with a compatible thermostat
  • Twinning of two furnaces with the accessory kit
  • Field-supplied filter or optional media filter cabinet

Warranty, as published

Default 5-year parts and 20-year heat exchanger limited warranties; 10-year parts and lifetime limited heat exchanger warranty with timely registration.

Register within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration. Original purchaser/homeowner only; see the warranty certificate. Source

BC Wide can help with registration and warranty enquiries for furnaces it installs or services. Ask about warranty support.

Manuals, codes and service

This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.

Questions people ask

Is 120,000 BTU/h ever right for a Vancouver-area house?

Occasionally, for large older houses with poor envelope performance, or where the duct system was designed around a big furnace. It is never chosen from square footage alone; the heat-loss calculation must support the capacity.

Why does the 120V24–22 show a cooling airflow range starting at only 165 CFM?

That is the low end of the selectable blower profile as printed in Carrier's product data (165 – 2130 CFM). Cooling airflow is set by the installer to the coil's requirement; the range is the control's capability, not a recommended setting.

Does this furnace need a special electrical circuit?

Carrier lists a 20 A maximum fuse or circuit breaker with 12 AWG minimum wire as the default. An optional low-amp kit allows a 15 A breaker with 14 AWG wire. The electrician sizes the branch circuit on site.

Considering the 59TP6C 120V24–22?