Carrier Performance 96 59TP6C 040V17–12

The 59TP6C 040V17–12 is Carrier's smallest Performance 96: 40,000 BTU/h input, 26,000 BTU/h on low fire, 39,000 BTU/h output on high, 96.0% AFUE upflow, in a 17.5-inch cabinet with a 1/2 HP variable-speed ECM blower. It is the size Carrier's data targets where the heating load is modest and the tightest fit and smallest venting count.

CurrentresidentialBC Wide service: confirm by phone

Rating plate

Model
59TP6C 040V17–12
Input
26,000 – 40,000 BTU/h
Output
25,000 – 39,000 BTU/h
AFUE
96% upflow · 95% down/horiz
Burner
Two-stage
Blower
ECM, constant torque (variable-speed)
Fuel
Natural gas / Propane
Cabinet
35 × 17.5 × 29.5 in
Canada
Available in Canada
Size designation as printed in Carrier product data 59TP6C-01PD. The complete 16-character number on the rating plate adds the voltage and minor-series digits; copy it from the plate when ordering parts.

On low fire this furnace burns 26,000 BTU/h and delivers 25,000 BTU/h; on high fire it burns 40,000 BTU/h and delivers 39,000 BTU/h. That makes it the only 59TP6C size Carrier's product data places below the 60,000 BTU/h step, and it is the size discussed for well-insulated bungalows, main-floor suites, laneway homes and other small houses in the Lower Mainland whose design heat loss sits under roughly 35,000 BTU/h.

Carrier's own product data warns that none of the 59TP6C sizes should be used where the heating load is 20,000 BTU/h or lower, and that excessive oversizing can cause premature failure, vent freezing and discomfort. A 40,000 BTU/h input furnace is not automatically right for a small house; the heat-loss calculation decides. Where a low load rules out a 95%+ furnace of any size, the conversation moves to alternatives such as a heat pump, not to a bigger furnace.

The 040V17–12 shares the family's two-stage Comfort Heat logic, variable 25-speed blower and two-speed inducer with the larger sizes, but it uses two burners and the smallest blower wheel in the family. Its certified AFUE is 96.0% upflow and 95.0% downflow or horizontal. The 14.2-inch-wide 040V14–10 sibling (14-3/16 in. cabinet, 126 lb) delivers the same inputs and outputs and is the 59TP6C size most likely to fit a narrow closet; Carrier's data gives it the same 96.0% upflow figure.

Specifications

From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.

Carrier Performance 96 59TP6C 040V17–12 specifications
SpecificationValueNote
Input
Input, high heat40,000 BTU/h
Input, low heat26,000 BTU/h
Output
Output capacity, high heat39,000 BTU/hCarrier product data; DOE test procedure, position dependent.
Output capacity, low heat25,000 BTU/h
Efficiency
AFUE, upflow96 %
AFUE, downflow / horizontal95 %
Airflow
Airflow, high heat @ rated ESP715 CFM
Airflow, low heat @ rated ESP540 CFM
Cooling airflow range205 – 1105 CFM
Cooling capacity match2.5 tons @ 400 CFM/ton; 3 tons @ 350 CFM/ton
Blower motorVariable 25-speed, constant-torque (VCT) ECMNot a constant-airflow motor; it does not report airflow to the control.
Certified temperature rise, high heat40 – 70 °F (22 – 39 °C)
Certified temperature rise, low heat30 – 60 °F (17 – 33 °C)
Physical
Cabinet width17.5 in445 mm
Shipping weight136 lb61.7 kg
Cabinet height35 in889 mm
Cabinet depth29.5 in750 mm
Installation positionsUpflow, downflow, horizontal left, horizontal right
Venting
VentingDirect vent (2-pipe), single-pipe, or ventilated combustion air; 2-in., 3-in. or optional 4-in. terminationMaximum equivalent vent length depends on size, pipe diameter and altitude; see installation instructions.
Electrical
Blower motor1/2 HP
Maximum unit amps7.4 A
Maximum fuse / breaker15 A
Electrical supply115 V, 60 Hz, 1 phase (104 – 127 V)
Controls
Burner stagingTwo-stage (low and high fire)
Other
InducerTwo-speed
FuelNatural gas; propane with CSA-listed conversion kit

Variants

Sizes that share this model page. A variant gets its own page only when it has substantial independent value.

Carrier Performance 96 59TP6C 040V17–12 variants
SizeInput highInput lowOutput highOutput lowAFUE upflowAFUE down/horizWidth (in)Ship wt (lb)Cooling CFMMotor HP
040V17–1240,00026,00039,00025,000969517.5136205 – 11051/2
040V14–1040,00026,00039,00025,000969514.19126135 – 10351/2

Filters, serial numbers and service parts

Filter

  • Field-supplied filter; certified watt data uses Carrier media filter 325531-40

Components this family's service documentation covers

  • Hot-surface ignitor
  • Flame sensor
  • Pressure switches (LPS/HPS)
  • Inducer motor
  • Condensate trap and drain components
  • ECM blower motor
  • Control board

Service-parts list source: Components documented for service in 59TP6C-01SI (edition 06/23).

Warranty coverage, registered or not

Registered
10-year parts and lifetime limited heat exchanger warranty
Not registered
Default 5-year parts and 20-year heat exchanger limited warranty

As published by the manufacturer. Source. Conditions and exceptions are in the warranty certificate.

Fault codes this model can show

Best for

  • Small detached homes, suites and laneway houses with design heat loss below roughly 35,000 BTU/h
  • Tight mechanical rooms and closets where the 17.5-inch or 14.2-inch cabinet is the deciding dimension
  • Homes pairing the furnace with a small air conditioner or heat pump of about 2 to 2.5 tons

Compatible controls

  • Standard 24 V thermostat terminals: G, C, W, Y/Y2, Y1, R, DHUM
  • ecobee for Carrier smart thermostat with InteliSense technology (InteliSense capable)
  • On-board 3-digit LCD control display for set-up, diagnostics and fault history

System integrations

  • Air conditioner or heat pump (dual-fuel / Hybrid Heat) with a compatible thermostat
  • Twinning of two furnaces with the accessory kit
  • Field-supplied filter or optional media filter cabinet

Warranty, as published

Default 5-year parts and 20-year heat exchanger limited warranties; 10-year parts and lifetime limited heat exchanger warranty with timely registration.

Register within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration. Original purchaser/homeowner only; see the warranty certificate. Source

BC Wide can help with registration and warranty enquiries for furnaces it installs or services. Ask about warranty support.

Manuals, codes and service

This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.

Questions people ask

Is 40,000 BTU/h too small for my house?

It depends entirely on the design heat loss. Many well-insulated Lower Mainland homes lose far less than 40,000 BTU/h on the coldest day, which is exactly the case this size exists for. A heat-loss calculation decides; square footage alone cannot.

What is the difference between the 040V17–12 and the 040V14–10?

Identical gas inputs and outputs and the same 96.0% upflow AFUE. The 040V14–10 is 3.3 inches narrower (14-3/16 in.), 10 lb lighter, and its blower tops out near 1,035 CFM of cooling airflow instead of 1,105 CFM.

Does the smallest furnace in the series cost less to run?

Running cost follows the heat loss of the house and the efficiency of the equipment, not the size alone. A correctly sized 040 will cycle properly; an oversized furnace of any size wastes gas in short cycles.

Considering the 59TP6C 040V17–12?

Get a published ballpark range for a supply-and-install, then a consultation to confirm sizing from a heat-loss assessment. Equipment-only pricing is not offered on this site.

Call Email Estimate