GasFurnace.caby BC Wide Heating & Air Conditioning

Carrier · Comfort 96 (59SC6A) · Model

Carrier Comfort 96 59SC6A 060M17–16

The 59SC6A 060M17–16 is the 60,000 BTU/h, 17.5-inch-wide Comfort 96: 58,000 BTU/h output on a single gas rate, 96.5% AFUE upflow, with a 3/4 HP multi-speed ECM blower. It is the entry-tier size most often matched to detached Lower Mainland houses with a real but modest heat loss.

CurrentresidentialBC Wide service: confirm by phone

Rating plate

Model
59SC6A 060M17–16
Input
undefined – 60,000 BTU/h
Output
undefined – 58,000 BTU/h
AFUE
96.5% upflow · 95% down/horiz
Burner
Single-stage
Blower
ECM, constant torque (variable-speed)
Fuel
Natural gas / Propane
Cabinet
35 × 17.5 × 29.5 in
Canada
Available in Canada
Size designation as printed in Carrier product data 59SC6A-01PD. The complete number on the rating plate adds the voltage and minor-series digits; copy it from the plate when ordering parts.

The Comfort 96 runs one gas rate, and this size delivers 58,000 BTU/h whenever the thermostat calls. That puts it squarely at the size band many 1950s to 1980s Lower Mainland detached homes calculate into after insulation upgrades, and where a single-stage furnace is an acceptable, lower-cost answer.

The 17.5-inch cabinet carries four burners and a 3/4 HP MCT ECM blower with up to 1,580 CFM of cooling airflow, enough for a mid-sized air conditioner or heat pump. Carrier certifies 96.5% AFUE upflow and horizontal, 95% downflow. The narrow 14.2-inch sibling (060M14–12) delivers 56,000 BTU/h at 95.0% AFUE and is the same capacity for a tighter closet.

Sizing still decides. A furnace that is oversized for the house short-cycles, and Carrier's product data is explicit that excessive oversizing can shorten furnace and vent life. Whether 60,000 BTU/h input is right is a heat-loss question, and BC Wide sizes from the calculation rather than from the furnace being replaced.

Specifications

From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.

Carrier Comfort 96 59SC6A 060M17–16 specifications
SpecificationValueNote
Input
Input60,000 BTU/h
Output
Output capacity58,000 BTU/hCarrier product data; DOE test procedure, position dependent.
Efficiency
AFUE, upflow / horizontal96.5 %
AFUE, downflow95 %
Airflow
Certified temperature rise range40 – 70 °F (22 – 39 °C)
Airflow, heating @ rated ESP1,030 CFM
Cooling airflow range315 – 1580 CFM
Blower motorMulti 18-speed, constant-torque (MCT) ECMNot a communicating constant-airflow motor; speeds are installer-selectable.
Physical
Cabinet width17.5 in445 mm
Shipping weight142 lb64 kg
Cabinet height35 in889 mm
Cabinet depth29.5 in750 mm
Installation positionsUpflow, downflow, horizontal left, horizontal right
Venting
VentingDirect vent (2-pipe), single-pipe, or ventilated combustion air on sizes above 26,000 BTU/h; the 26,000 BTU/h size uses 2-pipe venting with outside combustion air and is not classed as direct-vent
Electrical
Blower motor3/4 HP
Maximum unit amps10.1 A
Maximum fuse / breaker15 A
Electrical supply115 V, 60 Hz, 1 phase (104 – 127 V)
Controls
Burner stagingSingle-stage (full fire on every call)
Other
Burners4
InducerSingle-speed
FuelNatural gas; propane with gas conversion accessory kit

Variants

Sizes that share this model page. A variant gets its own page only when it has substantial independent value.

Carrier Comfort 96 59SC6A 060M17–16 variants
SizeInput highInput lowOutput highOutput lowAFUE upflowAFUE down/horizWidth (in)Ship wt (lb)Cooling CFMMotor HP
060M17–1660,00058,00096.59517.5142315 – 15803/4
060M14–1260,00056,000959514.19129200 – 11651/2

Filters, serial numbers and service parts

Filter

  • Field-supplied filter; certified watt data uses Carrier media filter 325531-40

Components this family's service documentation covers

  • Hot-surface ignitor
  • Flame sensor
  • Pressure switches
  • Inducer motor
  • Condensate trap and drain components
  • ECM blower motor
  • Control board

Service-parts list source: Components documented for service in 59SC6A-01SI REV D.

Fault codes this model can show

Best for

  • Detached homes with a verified design heat loss that 58,000 BTU/h can cover
  • Budget-conscious single-stage replacements on existing ducts
  • Homes pairing the furnace with a mid-sized air conditioner or heat pump of about 3 to 3.5 tons

Compatible controls

  • Standard 24 V thermostat terminals: G, C, W, Y, R
  • On-board 3-digit status display with NFC setup via the Carrier service technician app
  • EAC-1 (115 VAC), HUM (24 VAC) and 1-stage AC accessory connections

System integrations

  • Air conditioner or heat pump (dual-fuel / Hybrid Heat) with a compatible thermostat
  • Twinning of two furnaces with the accessory kit (selected sizes only)
  • Manufactured (mobile) home applications with the MH accessory kit (selected sizes)
  • Field-supplied filter or optional media filter cabinet

Manuals, codes and service

Compare

Guides that reference this model

This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.

Questions people ask

Is 60,000 BTU/h enough for a 2,000 sq ft house?

Square footage does not decide it. Two similar-looking houses can differ by a factor of two in heat loss. The 060M17–16 outputs 58,000 BTU/h, which a heat-loss calculation either supports or not.

How does this furnace differ from the two-stage 59TP6C 060V17–16?

Same tier family difference: the 59SC6A has one gas rate, a single-speed inducer and a lower first cost; the 59TP6C runs low fire most of the time and is quieter and steadier. Both are 95%+ condensing furnaces.

Considering the 59SC6A 060M17–16?

Get a published ballpark range for a supply-and-install, then a consultation to confirm sizing from a heat-loss assessment. Equipment-only pricing is not offered on this site.

Call Email Estimate