GasFurnace.caby BC Wide Heating & Air Conditioning

Carrier · Comfort 96 (59SC6A) · Model

Carrier Comfort 96 59SC6A 100M21–20

The 59SC6A 100M21–20 is the 100,000 BTU/h, 21-inch-wide Comfort 96: 97,000 BTU/h output on a single gas rate, 96.3% AFUE upflow, with a 1 HP multi-speed ECM blower. It serves larger, older or leakier houses whose heat-loss calculation lands above the 080 size.

CurrentresidentialBC Wide service: confirm by phone

Rating plate

Model
59SC6A 100M21–20
Input
undefined – 100,000 BTU/h
Output
undefined – 97,000 BTU/h
AFUE
96.3% upflow · 95% down/horiz
Burner
Single-stage
Blower
ECM, constant torque (variable-speed)
Fuel
Natural gas / Propane
Cabinet
35 × 21 × 29.5 in
Canada
Available in Canada
Size designation as printed in Carrier product data 59SC6A-01PD. The complete number on the rating plate adds the voltage and minor-series digits; copy it from the plate when ordering parts.

A single-stage furnace at 100,000 BTU/h input is a full-fire machine: every heating cycle burns at maximum until the thermostat is satisfied. For houses that genuinely calculate to this capacity, it is the least expensive honest answer in Carrier's line; for houses that do not, it is a short-cycling mistake, and Carrier's product data carries the usual warning that excessive oversizing can shorten furnace and vent life.

The 21-inch cabinet with five burners and a 1 HP MCT ECM blower moves 1,730 CFM in heating and up to 2,145 CFM for cooling. The 100M21–22 sibling in the same cabinet adds an extended airflow profile (up to 2,240 CFM) at the same certified 96.3% upflow.

Among Lower Mainland homes this size appears most in pre-1960 houses with original envelopes and little insulation, and in retrofit jobs where the calculation confirms the old furnace was not oversized. When a house has been upgraded since its old furnace was installed, the number usually comes back lower.

Specifications

From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.

Carrier Comfort 96 59SC6A 100M21–20 specifications
SpecificationValueNote
Input
Input100,000 BTU/h
Output
Output capacity97,000 BTU/hCarrier product data; DOE test procedure, position dependent.
Efficiency
AFUE, upflow / horizontal96.3 %
AFUE, downflow95 %
Airflow
Certified temperature rise range40 – 70 °F (22 – 39 °C)
Airflow, heating @ rated ESP1,730 CFM
Cooling airflow range375 – 2145 CFM
Blower motorMulti 18-speed, constant-torque (MCT) ECMNot a communicating constant-airflow motor; speeds are installer-selectable.
Physical
Cabinet width21 in533 mm
Shipping weight167 lb76 kg
Cabinet height35 in889 mm
Cabinet depth29.5 in750 mm
Installation positionsUpflow, downflow, horizontal left, horizontal right
Venting
VentingDirect vent (2-pipe), single-pipe, or ventilated combustion air on sizes above 26,000 BTU/h; the 26,000 BTU/h size uses 2-pipe venting with outside combustion air and is not classed as direct-vent
Electrical
Blower motor1 HP
Maximum unit amps12.6 A
Maximum fuse / breaker15 A
Electrical supply115 V, 60 Hz, 1 phase (104 – 127 V)
Controls
Burner stagingSingle-stage (full fire on every call)
Other
Burners5
InducerSingle-speed
FuelNatural gas; propane with gas conversion accessory kit

Variants

Sizes that share this model page. A variant gets its own page only when it has substantial independent value.

Carrier Comfort 96 59SC6A 100M21–20 variants
SizeInput highInput lowOutput highOutput lowAFUE upflowAFUE down/horizWidth (in)Ship wt (lb)Cooling CFMMotor HP
100M21–20100,00097,00096.39521167375 – 21451
100M21–22100,00097,00096.39521167450 – 22401

Filters, serial numbers and service parts

Filter

  • Field-supplied filter; certified watt data uses Carrier media filter 325531-40

Components this family's service documentation covers

  • Hot-surface ignitor
  • Flame sensor
  • Pressure switches
  • Inducer motor
  • Condensate trap and drain components
  • ECM blower motor
  • Control board

Service-parts list source: Components documented for service in 59SC6A-01SI REV D.

Fault codes this model can show

Best for

  • Larger and older detached homes with higher verified design heat loss
  • Houses with a 4- to 5-ton air conditioner or heat pump on shared ductwork
  • Replacements where the heat-loss calculation genuinely supports the capacity

Compatible controls

  • Standard 24 V thermostat terminals: G, C, W, Y, R
  • On-board 3-digit status display with NFC setup via the Carrier service technician app
  • EAC-1 (115 VAC), HUM (24 VAC) and 1-stage AC accessory connections

System integrations

  • Air conditioner or heat pump (dual-fuel / Hybrid Heat) with a compatible thermostat
  • Twinning of two furnaces with the accessory kit (selected sizes only)
  • Manufactured (mobile) home applications with the MH accessory kit (selected sizes)
  • Field-supplied filter or optional media filter cabinet

Manuals, codes and service

This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.

Questions people ask

When does a house actually need 100,000 BTU/h in the Lower Mainland?

Only when the heat-loss calculation says so. Many larger houses calculate below this after insulation and window upgrades. Ask for the calculation before accepting a size this big.

What is the difference between the 100M21–20 and the 100M21–22?

Identical input, output and certified AFUE in the same cabinet. The 100M21–22 has the extended blower airflow profile (up to 2,240 CFM for cooling versus 2,145 CFM).

Considering the 59SC6A 100M21–20?

Get a published ballpark range for a supply-and-install, then a consultation to confirm sizing from a heat-loss assessment. Equipment-only pricing is not offered on this site.

Call Email Estimate