Carrier · Performance 96 single-stage (59SP6B) · Model
Carrier Performance 96 single-stage 59SP6B 100V21–20
The 59SP6B 100V21–20 is the 100,000 BTU/h, 21-inch-wide single-stage Performance 96: 97,000 BTU/h output at one gas rate, 96.3% AFUE upflow, with a 1 HP variable-speed ECM blower. It serves larger, older houses whose heat-loss calculation lands above the 080 size.
Rating plate
- Model
- 59SP6B 100V21–20
- Input
- undefined – 100,000 BTU/h
- Output
- undefined – 97,000 BTU/h
- AFUE
- 96.3% upflow · 95% down/horiz
- Burner
- Single-stage
- Blower
- ECM, constant torque (variable-speed)
- Fuel
- Natural gas / Propane
- Cabinet
- 35 × 21 × 29.5 in
- Canada
- Available in Canada
A single-stage furnace at 100,000 BTU/h input burns at maximum on every heating cycle: 97,000 BTU/h of output until the thermostat is satisfied. Carrier certifies this size at 96.3% AFUE upflow and 95% downflow and horizontal, with a 1 HP blower moving 1,695 CFM in heating and up to 2,120 CFM for cooling.
The 21-inch cabinet holds five burners. An optional low-amp kit (KGAPC0101ECM) lets the furnace run on a 15 A breaker with 14 AWG wire where the default 20 A circuit is inconvenient, within the listed wire lengths.
Houses that genuinely calculate to 100,000 BTU/h are uncommon among newer Lower Mainland homes. Carrier's product data carries the standing warning against excessive oversizing, and the size is chosen from the calculation rather than from the old furnace's rating plate.
Specifications
From Carrier's published product data. Input and output are listed separately; AFUE depends on installation position.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input | 100,000 BTU/h | |
| Output | ||
| Output capacity | 97,000 BTU/h | Carrier product data; DOE test procedure, position dependent. |
| Efficiency | ||
| AFUE, upflow | 96.3 % | |
| AFUE, downflow / horizontal | 95 % | |
| Airflow | ||
| Airflow, heating @ rated ESP | 1,695 CFM | |
| Cooling airflow range | 400 – 2120 CFM | |
| Cooling capacity match | 5 tons @ 400 CFM/ton; 5.5 tons @ 350 CFM/ton | |
| Blower motor | Variable 25-speed, constant-torque (VCT) ECM | Not a constant-airflow motor; it does not report airflow to the control. |
| Certified temperature rise range | 40 – 70 °F (22 – 39 °C) | |
| Physical | ||
| Cabinet width | 21 in | 533 mm |
| Shipping weight | 172 lb | 78.0 kg |
| Cabinet height | 35 in | 889 mm |
| Cabinet depth | 29.5 in | 750 mm |
| Installation positions | Upflow, downflow, horizontal left, horizontal right | |
| Venting | ||
| Venting | Direct vent (2-pipe), single-pipe, or ventilated combustion air | Maximum equivalent vent length depends on size, pipe diameter and altitude; see installation instructions. |
| Electrical | ||
| Blower motor | 1 HP | |
| Maximum unit amps | 13.2 A | 11.3 A with the low-amp kit (KGAPC0101ECM) |
| Maximum fuse / breaker | 20 A | 15 A with the low-amp kit (14 AWG minimum wire) |
| Electrical supply | 115 V, 60 Hz, 1 phase (104 – 127 V) | |
| Controls | ||
| Burner staging | Single-stage (full fire on every call) | |
| Other | ||
| Burners | 5 | |
| Inducer | Single-speed | |
| Fuel | Natural gas; propane with gas conversion accessory kit | |
Filters, serial numbers and service parts
Filter
- Field-supplied filter; certified watt data uses Carrier media filter 325531-40
Components this family's service documentation covers
- Hot-surface ignitor
- Flame sensor
- Pressure switches
- Inducer motor
- Condensate trap and drain components
- ECM blower motor
- Control board
Service-parts list source: Components documented for service in 59SP6B-01SI REV B.
Warranty coverage, registered or not
- Registered
- 10-year parts and lifetime limited heat exchanger warranty
- Not registered
- Default 5-year parts and 20-year heat exchanger limited warranty
As published by the manufacturer. Source. Conditions and exceptions are in the warranty certificate.
Fault codes this model can show
Best for
- Larger and older detached homes with higher verified design heat loss
- Houses with a 4- to 5-ton air conditioner or heat pump on shared ductwork
- Replacements where the heat-loss calculation supports the capacity
Compatible controls
- Standard 24 V thermostat terminals: G, C, W, Y/Y2, Y1, R, DHUM
- ecobee for Carrier smart thermostat with InteliSense technology (InteliSense capable)
- On-board 3-digit LCD control display with ComfortFan continuous-fan control
System integrations
- Air conditioner or heat pump (dual-fuel / Hybrid Heat) with a compatible thermostat
- Twinning of two furnaces with the accessory kit
- Field-supplied filter or optional media filter cabinet
Warranty, as published
Default 5-year parts limited warranty and 20-year heat exchanger limited warranty; 10-year parts and lifetime limited heat exchanger warranty with timely registration.
Register within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration. Original purchaser/homeowner only; see the warranty certificate. Source
BC Wide can help with registration and warranty enquiries for furnaces it installs or services. Ask about warranty support.
Manuals, codes and service
Documents
Fault codes that apply
- Code 23: pressure switch stuck closed
- Code 24: fuse fault
- Code 25: control program and configuration faults
- Code 27: super plug or control program fault
- Code 31: secondary pressure switch open or lockout
- Code 32: open main pressure switch (LPS)
- Code 33: a switch has opened in the main limit circuit
- Code 34: ignition fault or flame loss
- Code 45: control failure
- Code 46: momentary loss of power
- Code 10: rapid flash - L1 polarity fault
- Code 12: W on at power up
- Code 13: limit lockout or ignition lockout
- Code 14: flame-loss lockouts during a heat request
- Code 21: 24 VAC sensed on the gas valve when it shouldn't be
- Code 22: false flame
- Code 15: lockout - no blower rpms detected
- Code 19: InteliSense communications loss
- Code 41: blower RPM not detected
- Code 52: supply-air temperature sensor open or short
- Code 53: return-air temperature sensor open or short
BC Wide service
This catalogue page is reference information for anywhere in Canada. On-site service for this model is available across Greater Vancouver from BC Wide's Burnaby base — see furnace service in Burnaby and all service areas.
Questions people ask
Why is the upflow AFUE 96.3% on this size when smaller sizes certify at 97%?
Certified AFUE is a per-size figure. Carrier publishes 97.0% for the 060 and 080 sizes of this family and 96.3% for the 100V21–20 and 96.1% for the 120V24–22; the rating plate carries the figure for your size.
Does this furnace need a 20-amp circuit?
Carrier lists a 20 A maximum breaker with 12 AWG wire by default for this size. An optional low-amp kit allows 15 A with 14 AWG wire; the electrician confirms on site.