Carrier · Service
Carrier Condensate Management
BC Wide installs and services condensate systems for condensing furnaces: trap orientation per the installation position, drain routing and slope, condensate pumps where there is no gravity drain, and freeze protection where the drain runs through cold space. This page covers Carrier furnaces specifically.
Condensate done right: drains, traps, pumps and winterization
Service at a glance
- Provider
- BC Wide Heating & Air Conditioning
- Where
- Greater Vancouver, BC
- Hours
- Monday–Thursday 7 am–10 pmFriday 7:30 am–10 pmSaturday 8 am–6 pmSunday 10 am–5 pm
- Emergency
- Subject to availability
- Phone
- 604-473-9690
A condensing furnace makes litres of mildly acidic water a day in cold weather, and the entire appliance depends on that water leaving continuously. The trap is part of the flue-gas seal, the drain must fall to its termination or pump, and anything that blocks or freezes the path stops the furnace through its pressure-switch or drain safeties.
Installation work follows the manufacturer's trap and drain instructions for the specific furnace and its mounting position (this site's model pages link those instructions). Service work covers blocked traps, flooded collector boxes, failed condensate pumps and drains that freeze or back up.
Winterization is part of the service story: drains through unheated space and exterior terminations need the protection the manufacturer specifies, which Carrier, for example, documents as a propylene-glycol procedure for installations where the drain can freeze.
Carrier specifics
Carrier sells residential gas furnaces in Canada through its Canadian site and dealer network, in three tiers: Comfort, Performance and Infinity. Furnaces range from single-stage models to modulating units with variable-speed blowers, and all current sizes are design certified in Canada.
BC Wide lists Carrier among the brands it works on. Factory-authorized dealer status for Carrier has not been confirmed and is not claimed here.
- 59TP6C 060V17–16
- 59TP6C 080V21–20
- 59TP6C 040V17–12
- 59TP6C 100V21–20
- 59TP6C 120V24–22
- 59SC6A 026M14–10
- 59SC6A 040M17–12
- 59SC6A 060M17–16
- 59SC6A 080M21–20
- 59SC6A 100M21–20
- 59SC6A 120M24–22
- 59SC6A 140M24–22
- 59TP7A 060V17–16
- 59TP7A 080V21–20
- 59TP7A 100V21–20
- 59TP7A 120V24–22
- 59SP6B 040V17–12
- 59SP6B 060V17–16
- 59SP6B 080V21–20
- 59SP6B 100V21–20
- 59SP6B 120V24–22
- 59TN6B 060C17–14
- 59TN6B 080C21–20
- 59TN6B 100C21–22
- 59TN6B 120C24–22
- 59TN7A 060C17–16
- 59TN7A 080C21–20
- 59TN7A 100C21–22
- 59TN7A 120C24–22
- 59MN7C 060C21–20
- 59MN7C 080C21–20
- 59MN7C 100C21–22
- 59MN7C 120C24–22
- Code 23
- Code 24
- Code 25
- Code 27
- Code 31
- Code 32
- Code 33
- Code 34
- Code 45
- Code 46
- Code 10
- Code 12
- Code 13
- Code 14
- Code 21
- Code 22
- Code 31
- Code 10
- Code 12
- Code 13
- Code 14
- Code 15
- Code 19
- Code 21
- Code 22
- Code 23
- Code 24
- Code 25
- Code 27
- Code 32
- Code 33
- Code 34
- Code 41
- Code 43
- Code 45
- Code 46
- Code 52
- Code 53
- Code 31
- Code 10
- Code 12
- Code 13
- Code 14
- Code 15
- Code 19
- Code 21
- Code 22
- Code 23
- Code 24
- Code 25
- Code 27
- Code 32
- Code 33
- Code 34
- Code 41
- Code 43
- Code 45
- Code 46
- Code 52
- Code 53
- Code 23
- Code 24
- Code 25
- Code 27
- Code 31
- Code 32
- Code 33
- Code 34
- Code 45
- Code 46
- Code 10
- Code 12
- Code 13
- Code 14
- Code 21
- Code 22
- Code 15
- Code 19
- Code 41
- Code 52
- Code 53
- Code 31
- Code 10
- Code 12
- Code 13
- Code 14
- Code 21
- Code 22
- Code 23
- Code 24
- Code 25
- Code 27
- Code 32
- Code 43
- Code 45
- Code 52
- Code 53
- Code 15
- Code 41
- Code 51
- Code 33
- Code 34
What is included
- Condensate trap installation and orientation for the furnace position
- Drain routing, slope and termination or condensate pump installation
- Trap, drain and collector-box cleaning at service visits
- Freeze-protection and winterization where the installation needs it
What is not included
- Plumbing connections to sanitary drains beyond the furnace drain, unless quoted
- Condensate neutralizers, where local rules require them, quoted separately
Permits: None for trap and drain service; new connections to sanitary drains may require a plumbing permit, confirmed on site
When not to DIY
- The condensate trap is part of the flue-gas seal; never open it on a running furnace
How it works
Check the path
Trap orientation, drain slope, pump and termination are reviewed.
Install or clean
Trap, drain or pump work is done per the manufacturer's instructions.
Verify
The furnace runs a full cycle and the water path is confirmed end to end.
Questions people ask
Why is water around my furnace?
The condensate path is blocked, frozen or disconnected: a clogged trap, a sagging drain, a failed pump or a frozen termination. Turn off a flooding pump, mop up, and call; the furnace may stop on its own with a pressure-switch code.
Can I clean the condensate trap myself?
The trap is part of the flue-gas seal on a gas appliance. Cleaning it is a technician's job; opening it on a running furnace is not safe.
Is condensate dangerous?
It is mildly acidic, so it can damage flooring and rust equipment, but it is not a gas or CO hazard by itself. The hazard is running a furnace whose trap is not sealing, which is why the repair is left to a technician.
Who does the work
Technical Safety BC Licensed Gas Contractor
Licence LGA0090068, BC Wide Home Services Ltd
Source, checked 2026-09-07
BC Wide states its work is done by TSBC-licensed gas fitters and Red Seal technicians. Source
Reviews of BC Wide Heating & Air Conditioning are published on Google. This site shows no rating or count until the live figure is copied on a known date, because bcwide.ca currently states two different totals.
On-site furnace service across Greater Vancouver by BC Wide Heating & Air Conditioning
Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Delta, Langley, Port Moody, Port Coquitlam, White Rock, Pitt Meadows, Maple Ridge, Tsawwassen, Ladner, Anmore, Belcarra, Lions Bay.
Canada-wide gas furnace information: brand, model and error-code pages are reference material for anyone in Canada. Technicians are dispatched from Burnaby only.
Related
- ServiceFurnace MaintenanceAnnual furnace maintenance that checks what actually fails
- ServiceGas Furnace RepairFurnace repair in Greater Vancouver, diagnosed before parts are replaced
- ServiceGas Furnace InstallationNew furnace installation sized from a heat-loss calculation, not from the old furnace
- SymptomFurnace not heating
- ComponentCondensate trap, drain and pump
- ComponentFurnace pressure switch
See a ballpark range before you talk to anyone
Answer a few questions and get a published CAD range with the assumptions spelled out. No contact details needed to see it.