GasFurnace.caby BC Wide Heating & Air Conditioning

Lennox · Series

Lennox Dave Lennox Signature Collection SLP99V

The Lennox Dave Lennox Signature Collection SLP99V is rated up to 99% AFUE and delivers a modulating burner; Lennox lists it as part of its current Dave Lennox Signature Collection as of 2026-09-09.

Series rating plate

Family code
SLP99V
Tier
Dave Lennox Signature Collection
Burner
Modulating
Blower
ECM, variable-speed
AFUE claim
Up to 99% AFUE
Fuel
Natural gas / Propane
Positions
Control
Lennox controls by generation; documented from the installation manual as records are verified.
Production
Current Lennox family listed on lennox.com as of 2026-09-09; introduction year to be read from official product data.
Status
Current · Canadian availability not verified
Listed on Lennox's official site (lennox.com, accessed 2026-09-09). A separate Canadian availability statement was not machine-readable on that date; BC Wide services Lennox furnaces across Greater Vancouver.

The SLP99V sits in Lennox's Dave Lennox Signature Collection. As of 2026-09-09 it is listed on Lennox's official site, which rates it up to 99% AFUE. It is a condensing furnace, so an installation uses plastic (PVC/CPVC) venting and needs a condensate drain.

The SLP99V delivers a modulating burner and uses an ECM variable-speed blower, as stated on Lennox's official product page (read 2026-09-09). Model-by-model capacities, cabinet sizes and clearances come from Lennox product data and installation literature, which this site adds to each record as it is verified; until then the rating plate remains the authority for the exact model.

BC Wide services SLP99V furnaces across Greater Vancouver: diagnosis and error-code reads, repairs, tune-ups and maintenance, and replacement with an equivalent current model. Technicians work from the full rating-plate model number, so family-level pages like this one are an entry point rather than a substitute for the model record.

Highlights from the manufacturer's product data

  • Up to 99% AFUE gas furnace
  • Staging: modulating
  • Blower: ECM variable speed
  • Condensing, plastic venting

Models in this series

Capacity and width variants documented on this site. Values from the manufacturer's product data; “—” means not published there.

Series variants
SizeInput high (BTU/h)Input low (BTU/h)Output high (BTU/h)AFUE upflow (%)AFUE down/horiz (%)Width (in)Page
SLP99DF070XV36B*66,00064,00097.5Model page
SLP99DF070XV36B-*66,00064,00097.5Variant
SLP99DF090XV36C*88,00085,00097.5Model page
SLP99DF090XV36C-*88,00085,00097.5Variant
SLP99DF090XV48C*88,00085,00097.5Model page
SLP99DF090XV48C-*88,00085,00097.5Variant
SLP99DF090XV60C*88,00085,00097.5Model page
SLP99DF090XV60C-*88,00085,00097.5Variant
SLP99DF110XV60C*110,000107,00097.5Model page
SLP99DF110XV60C-*110,000107,00097.5Variant
SLP99UH070XV36B*66,00064,00098.198.1Model page
SLP99UH070XV36B-*66,00064,00098.198.1Variant
SLP99UH090XV36C*88,00086,00098.198.1Model page
SLP99UH090XV36C-*88,00086,00098.198.1Variant
SLP99UH090XV48C*88,00086,00098.298.2Model page
SLP99UH090XV48C-*88,00086,00098.298.2Variant
SLP99UH090XV60C*88,00086,0009999Model page
SLP99UH090XV60C-*88,00086,0009999Variant
SLP99UH110XV60C*110,000107,00098.198.1Model page
SLP99UH110XV60C-*110,000107,00098.198.1Variant
SLP99UH135XV60D*132,000129,00098.498.4Model page
SLP99UH135XV60D-*132,000129,00098.498.4Variant

Venting

Condensing: vented with plastic (PVC/CPVC) pipe per Lennox installation instructions; condensate drainage required.

Factory natural-gas rating; the rating plate states the fuel. Fuel changes on gas appliances belong to licensed technicians using the manufacturer's conversion procedure.

Controls and integrations

  • Standard 24 V thermostat control; staging behaviour follows the thermostat call (or Lennox communicating controls where the family supports them).
  • Controller- and model-specific setup is documented in the Lennox installation instructions for this family.

Fault codes for this series

No codes documented yet for this series. See the Lennox index.

Manuals and documents

    Questions people ask

    Does BC Wide service the SLP99V?

    Yes. BC Wide's published furnace-brands list includes Lennox, and its technicians diagnose, repair, maintain and replace Lennox gas furnaces from the rating-plate model number across Greater Vancouver. Call 604-473-9690.

    Is the SLP99V still sold?

    Lennox's official site lists this family as of 2026-09-09 (source on this page). Canadian sale availability is confirmed by a Lennox dealer; this site's Canadian-availability label is updated as official evidence is read.

    Where do I find the exact model of my SLP99V?

    On the rating plate inside the blower door: Lennox model numbers start with the family code, for example SLP99V, followed by cabinet and size characters. Send the full number to BC Wide for parts and service confirmation.

    Talk it through before you decide

    A consultation covers sizing, staging, venting and whether a heat pump belongs in the plan. No purchase required.

    Call Email Estimate