GasFurnace.caby BC Wide Heating & Air Conditioning

Lennox · Series

Lennox Elite Series EL297V

The Lennox Elite Series EL297V is rated up to 97% AFUE and delivers two-stage heating; Lennox lists it as part of its current Elite Series as of 2026-09-09.

Series rating plate

Family code
EL297V
Tier
Elite Series
Burner
Two-stage
Blower
ECM, variable-speed
AFUE claim
Up to 97% AFUE
Fuel
Natural gas / Propane
Positions
Control
Lennox controls by generation; documented from the installation manual as records are verified.
Production
Current Lennox family listed on lennox.com as of 2026-09-09; introduction year to be read from official product data.
Status
Current · Canadian availability not verified
Listed on Lennox's official site (lennox.com, accessed 2026-09-09). A separate Canadian availability statement was not machine-readable on that date; BC Wide services Lennox furnaces across Greater Vancouver.

The EL297V sits in Lennox's Elite Series. As of 2026-09-09 it is listed on Lennox's official site, which rates it up to 97% AFUE. It is a condensing furnace, so an installation uses plastic (PVC/CPVC) venting and needs a condensate drain.

The EL297V delivers two-stage heating and uses an ECM variable-speed blower, as stated on Lennox's official product page (read 2026-09-09). Model-by-model capacities, cabinet sizes and clearances come from Lennox product data and installation literature, which this site adds to each record as it is verified; until then the rating plate remains the authority for the exact model.

BC Wide services EL297V furnaces across Greater Vancouver: diagnosis and error-code reads, repairs, tune-ups and maintenance, and replacement with an equivalent current model. Technicians work from the full rating-plate model number, so family-level pages like this one are an entry point rather than a substitute for the model record.

Highlights from the manufacturer's product data

  • Up to 97% AFUE gas furnace
  • Staging: two stage
  • Blower: ECM variable speed
  • Condensing, plastic venting

Models in this series

Capacity and width variants documented on this site. Values from the manufacturer's product data; “—” means not published there.

Series variants
SizeInput high (BTU/h)Input low (BTU/h)Output high (BTU/h)AFUE upflow (%)AFUE down/horiz (%)Width (in)Page
EL297DF045XV36B*44,00043,00097Model page
EL297DF045XV36B-*44,00043,00097Variant
EL297DF070XV48B*66,00064,00097Model page
EL297DF070XV48B-*66,00064,00097Variant
EL297DF090XV60C*88,00086,00097Model page
EL297DF090XV60C-*88,00086,00097Variant
EL297DF110XV60C*110,000108,00097Model page
EL297DF110XV60C-*110,000108,00097Variant
EL297UH045XV36B*44,00043,0009797Model page
EL297UH045XV36B-*44,00043,0009797Variant
EL297UH070XV36B*66,00064,0009797Model page
EL297UH070XV36B-*66,00064,0009797Variant
EL297UH090XV36C*88,00085,0009797Model page
EL297UH090XV36C-*88,00085,0009797Variant
EL297UH090XV48C*88,00086,0009797Model page
EL297UH090XV48C-*88,00086,0009797Variant
EL297UH090XV60C*88,00086,0009797Model page
EL297UH090XV60C-*88,00086,0009797Variant
EL297UH110XV48C*110,000106,0009797Model page
EL297UH110XV48C-*110,000106,0009797Variant
EL297UH110XV60C*110,000107,0009797Model page
EL297UH110XV60C-*110,000107,0009797Variant
EL297UH135XV60D*132,000127,0009797Model page
EL297UH135XV60D-*132,000127,0009797Variant

Venting

Condensing: vented with plastic (PVC/CPVC) pipe per Lennox installation instructions; condensate drainage required.

Factory natural-gas rating; the rating plate states the fuel. Fuel changes on gas appliances belong to licensed technicians using the manufacturer's conversion procedure.

Controls and integrations

  • Standard 24 V thermostat control; staging behaviour follows the thermostat call (or Lennox communicating controls where the family supports them).
  • Controller- and model-specific setup is documented in the Lennox installation instructions for this family.

Fault codes for this series

No codes documented yet for this series. See the Lennox index.

Manuals and documents

    Questions people ask

    Does BC Wide service the EL297V?

    Yes. BC Wide's published furnace-brands list includes Lennox, and its technicians diagnose, repair, maintain and replace Lennox gas furnaces from the rating-plate model number across Greater Vancouver. Call 604-473-9690.

    Is the EL297V still sold?

    Lennox's official site lists this family as of 2026-09-09 (source on this page). Canadian sale availability is confirmed by a Lennox dealer; this site's Canadian-availability label is updated as official evidence is read.

    Where do I find the exact model of my EL297V?

    On the rating plate inside the blower door: Lennox model numbers start with the family code, for example EL297V, followed by cabinet and size characters. Send the full number to BC Wide for parts and service confirmation.

    Talk it through before you decide

    A consultation covers sizing, staging, venting and whether a heat pump belongs in the plan. No purchase required.

    Call Email Estimate