Component

Gas valve

The gas valve admits gas to the burners only when the control commands it after ignition conditions are met. Gas-valve faults are serious by nature: diagnosis checks that the valve opens when commanded, closes when not, and delivers the right pressure, and any work on it is licensed-gas-fitter work.

Short answer

If the furnace is not lighting and the ignitor glows but no gas flows, the gas valve may not be opening, or gas may not be reaching it: check the shut-off valve position first. Testing a gas valve involves measuring voltage at its terminals during the trial and checking pressures; that is licensed-gas-fitter work, and a valve that leaks or fails closed is replaced, not repaired.

How the valve works

The gas valve is electrically controlled and pressure regulated. The control energizes it only after draft is proven and the ignitor is hot; the valve opens, gas flows to the burners, and the flame sensor confirms ignition. Redundant valves contain multiple safety shutoffs by design.

Failure modes

A valve can fail to open (no gas, ignition codes), fail to close (gas flow with the furnace off, a serious condition some controls detect as false flame or as voltage where none should be), or regulate badly (wrong pressures, sooty or noisy burners). Failures are diagnosed by measuring the control's output, the valve's response and the pressures.

The rules around gas valves

Gas valves are not repaired in the field; they are replaced with the manufacturer's part. Pressure adjustments inside the valve follow the manufacturer's procedure and are gas-fitter work. If you ever smell gas, leave the building and call FortisBC at 1-800-663-9911 or 911 before anything else.

Related

Questions people ask

Is a gas valve failure an emergency?

A furnace that will not light because the valve will not open is a breakdown, not an emergency. A valve that lets gas flow when the furnace is off is an emergency: if you smell gas, leave and call FortisBC at 1-800-663-9911 or 911.

Can a gas valve be adjusted to fix a noisy burner?

Burner noise can come from pressure, orifices or burner condition. Adjusting valve pressure is gas-fitter work done with instruments, and only within the manufacturer's procedure.

Why does my furnace have two gas-valve codes?

Some controls detect 24 V at the valve circuit when it should not be there, or a valve relay that will not close. Both are documented on this site's code pages for the controls that show them.