Trane · Series
Trane TUHM (registry family)
Trane TUHM models are registered in Canada's national efficiency registry (NRCan EnerGuide, export read 2026-09-09); registry AFUE reaches 97.3% afue.
Series rating plate
- Family code
- TUHM
- Tier
- —
- Burner
- Modulating
- Blower
- ECM, variable-speed
- AFUE claim
- Up to 97.3% AFUE
- Fuel
- Propane
- Positions
- Upflow, Horizontal left, Horizontal right
- Status
- Current · Available in Canada
This series record groups the Trane TUHM gas-furnace nameplate families found in the official Canadian registry export of 2026-09-09. Certified efficiencies in the registry reach 97.3% afue.
Each model page under this series cites the registry listing for its exact identifier, input rating, heating capacity and certified AFUE. Orientation coverage is recorded from the registry configuration field; installation and control details are added as the manufacturer's literature is verified.
Highlights from the manufacturer's product data
- Up to 97.3% AFUE
- TUHM nameplate families in the NRCan registry
Models in this series
TUHMB060CCV3V
Trane TUHMB060CCV3V
Registry-verified Trane TUHMB060CCV3V gas furnace: Up to 97.3% AFUE, listed in Canada's NRCan EnerGuide registry (2026-09-09).
TUHMB080CCV3V
Trane TUHMB080CCV3V
Registry-verified Trane TUHMB080CCV3V gas furnace: Up to 97% AFUE, listed in Canada's NRCan EnerGuide registry (2026-09-09).
TUHMC100CCV4V
Trane TUHMC100CCV4V
Registry-verified Trane TUHMC100CCV4V gas furnace: Up to 96% AFUE, listed in Canada's NRCan EnerGuide registry (2026-09-09).
TUHMD120CCV5V
Trane TUHMD120CCV5V
Registry-verified Trane TUHMD120CCV5V gas furnace: Up to 97% AFUE, listed in Canada's NRCan EnerGuide registry (2026-09-09).
Capacity and width variants documented on this site. Values from the manufacturer's product data; “—” means not published there.
| Size | Input high (BTU/h) | Input low (BTU/h) | Output high (BTU/h) | AFUE upflow (%) | AFUE down/horiz (%) | Width (in) | Page |
|---|---|---|---|---|---|---|---|
| TUHMB060CCV3V** | 60,000 | — | 58,000 | 97.3 | — | — | Model page |
| TUHMB060CCV3V**-H | 60,000 | — | 57,000 | — | 96.5 | — | Variant |
| TUHMB080CCV3V** | 80,000 | — | 76,000 | 97 | — | — | Model page |
| TUHMB080CCV3V**-H | 80,000 | — | 76,000 | — | 96.2 | — | Variant |
| TUHMC100CCV4V** | 100,000 | — | 96,000 | 96 | — | — | Model page |
| TUHMC100CCV4V**-H | 100,000 | — | 95,000 | — | 95.2 | — | Variant |
| TUHMD120CCV5V** | 120,000 | — | 116,000 | 97 | — | — | Model page |
| TUHMD120CCV5V**-H | 120,000 | — | 114,000 | — | 96.2 | — | Variant |
Venting
Condensing furnace (registry AFUE 95 percent or higher); plastic venting and condensate details come from the manufacturer's installation literature.
Fault codes for this series
No codes documented yet for this series. See the Trane index.
Manuals and documents
Talk it through before you decide