Rheem · Series
Rheem R98MV (registry family)
Rheem R98MV models are registered in Canada's national efficiency registry (NRCan EnerGuide, export read 2026-09-09); registry AFUE reaches 98% afue.
Series rating plate
- Family code
- R98MV
- Tier
- —
- Burner
- Modulating
- Blower
- ECM, variable-speed
- AFUE claim
- Up to 98% AFUE
- Fuel
- Natural gas
- Positions
- Upflow, Horizontal left, Horizontal right
- Status
- Current · Available in Canada
This series record groups the Rheem R98MV gas-furnace nameplate families found in the official Canadian registry export of 2026-09-09. Certified efficiencies in the registry reach 98% afue.
Each model page under this series cites the registry listing for its exact identifier, input rating, heating capacity and certified AFUE. Orientation coverage is recorded from the registry configuration field; installation and control details are added as the manufacturer's literature is verified.
Highlights from the manufacturer's product data
- Up to 98% AFUE
- R98MV nameplate families in the NRCan registry
Models in this series
R98MV0603A17UPS
Rheem R98MV0603A17UPS
Registry-verified Rheem R98MV0603A17UPS gas furnace: Up to 98% AFUE, listed in Canada's NRCan EnerGuide registry (2026-09-09).
R98MV0703A17UPS
Rheem R98MV0703A17UPS
Registry-verified Rheem R98MV0703A17UPS gas furnace: Up to 98% AFUE, listed in Canada's NRCan EnerGuide registry (2026-09-09).
R98MV0855A21UPS
Rheem R98MV0855A21UPS
Registry-verified Rheem R98MV0855A21UPS gas furnace: Up to 98% AFUE, listed in Canada's NRCan EnerGuide registry (2026-09-09).
R98MV1005A21UPS
Rheem R98MV1005A21UPS
Registry-verified Rheem R98MV1005A21UPS gas furnace: Up to 98% AFUE, listed in Canada's NRCan EnerGuide registry (2026-09-09).
R98MV1155A24UPS
Rheem R98MV1155A24UPS
Registry-verified Rheem R98MV1155A24UPS gas furnace: Up to 98% AFUE, listed in Canada's NRCan EnerGuide registry (2026-09-09).
Capacity and width variants documented on this site. Values from the manufacturer's product data; “—” means not published there.
| Size | Input high (BTU/h) | Input low (BTU/h) | Output high (BTU/h) | AFUE upflow (%) | AFUE down/horiz (%) | Width (in) | Page |
|---|---|---|---|---|---|---|---|
| R98MV0603A17UPS | 56,000 | — | 55,000 | 98 | — | — | Model page |
| R98MV0703A17UPS | 70,000 | — | 69,000 | 98 | — | — | Model page |
| R98MV0855A21UPS | 84,000 | — | 82,000 | 98 | — | — | Model page |
| R98MV1005A21UPS | 98,000 | — | 96,000 | 98 | — | — | Model page |
| R98MV1155A24UPS | 112,000 | — | 110,000 | 98 | — | — | Model page |
Venting
Condensing furnace (registry AFUE 95 percent or higher); plastic venting and condensate details come from the manufacturer's installation literature.
Fault codes for this series
No codes documented yet for this series. See the Rheem index.