Carrier Infinity 97 vs Infinity 98: the 80,000 BTU/h communicating furnaces

A same-size comparison of Carrier's communicating two-stage Infinity 97 and modulating Infinity 98, using Carrier's published product data for both.

Short answer

The Infinity 97 (59TN7A 080C21–20) is a communicating two-stage furnace: low and high fire at 52,000 and 80,000 BTU/h input. The Infinity 98 (59MN7C 080C21–20) is the modulating version: its input steps continuously from 32,000 to 80,000 BTU/h, with a variable-speed inducer and a certified 97.2% AFUE. The 98 is Carrier's most precise and most expensive residential furnace; the 97 delivers two-stage comfort on the same communicating platform for less.

Carrier Infinity 97 vs Infinity 98: the 80,000 BTU/h communicating furnaces
Specification59TN7A 080C21–2059MN7C 080C21–20
AFUE, upflow97 %97.2 %
AFUE, horizontal96.7 %
AFUE, downflow95 %95 %
Cabinet width21 in21 in
Approximate shipping weight171.5 lb161 lb
Cooling airflow @ 0.5 in. w.c.1,985 CFM2,035 CFM
Cooling capacity match4.5 tons @ 400 CFM/ton; 5.5 tons @ 350 CFM/ton4.5 tons @ 400 CFM/ton; 5.5 tons @ 350 CFM/ton
Blower motor1 HP1 HP
Maximum unit amps13.1 A14.4 A
Maximum fuse / breaker20 A20 A

Staging is the whole story. The Infinity 97 has two gas rates: 52,000 BTU/h input on low fire and 80,000 BTU/h on high, with outputs of 50,000 and 76,000 BTU/h. The Infinity 98 modulates: Carrier publishes 32,000 BTU/h minimum, 52,000 BTU/h intermediate and 80,000 BTU/h maximum inputs, with outputs of 31,000, 51,000 and 78,000 BTU/h, plus a variable-speed inducer matched to the burner.

Efficiency is close: Carrier certifies the Infinity 97 at 97.0% AFUE upflow and 96.7% horizontal, and the Infinity 98 at 97.2% upflow and horizontal, both 95.0% downflow. The efficiency gap is not the reason to buy the 98; the reason is low-capacity operation: on mild days the 98 can hold the house at minimum fire instead of cycling between off and full.

Both are communicating furnaces for the Infinity system with constant-airflow ECM blowers, in the same 21-inch cabinets with similar electrical requirements (20 A maximum breaker on each). The 98 adds the modulating gas valve, variable-speed inducer and the 98.5%-certified 060C21–20 sibling at the small end of the family.

Which one wins depends on the house: steady small heat loss favors the 98's long low-fire runs; a house that rarely needs less than low-fire output pays for modulation it cannot use. Sizing follows a heat-loss calculation for both, and the 98's set-up and control configuration matter more than on any other family here.

Questions people ask

Is the Infinity 98 much more efficient than the Infinity 97?

No: 97.2% versus 97.0% upflow in Carrier's data for these sizes. The 98's value is its modulating range and steadier low-capacity operation, not its AFUE.

Can the Infinity 97 do what the Infinity 98 does?

No. The 97 steps between two gas rates; the 98 varies continuously across its range. If most of the heating season is mild, the modulating furnace runs at low capacity for long periods, which is the comfort difference.